Skip to main content
Schneider Electric GVAED101

Schneider GVAED101 Aux Contact Block, 2 NO, 2.5 A

MPNGVAED101
Active

Schneider TeSys Deca GVAED101 auxiliary contact block, 2 NO fault signal contacts, dark grey, 45 mm wide, rated insulation voltage 690 V.

$6.68Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

GVAED101 key specifications
ParameterValue
Protection typeGB2CB... circuit breaker GG fuse 10 A
Product or component typeAuxiliary contact block
Minimum switching voltage17 V
Voltage600 V UL 508 690 V IEC 60947-1 600 V CSA C22.2 No 14
[Ue] rated operational voltage24...240 V AC 24...60 V DC
Minimum switching current5 mA
[Ith] conventional free air thermal current2.5 A
Rated operational power in120 W 240 V DC-13 100000 cycles 140 W 110 V DC-13 100000 cycles 140 W 24 V DC-13 100000 cycles 180 W 60 V DC-13 100000 cycles 240 W 48 V DC-13 100000 cycles
Pole contact composition2 NO
Mounting locationFront side
ColorDark grey
Depth1.1 in (29 mm)

All specifications

GVAED101 additional specifications
ParameterValue
Width1.8 in (45 mm)
Height0.4 in (11 mm)
Mechanical durability100000 cycles
StandardsEN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-1:Clause 30.2 IEC/EN 60335-2-40:Annex JJ
RangeTeSys TeSys Deca
CategoryUS10I1122367
Quantity per setSet of 1
Device short nameGVAED
Tightening torque15.05 lbf.in (1.7 N.m) screw clamp terminals
Auxiliary contacts operationFault signal 1 NO
Environmental characteristicNormal environment

Product details

Schneider GVAED101 is an auxiliary contact block for the TeSys Deca manual starter range. It mounts on the front side and adds a set of two normally-open (2 NO) fault signal contacts. That's one spare SKU for the bin if you're standardizing on that starter family. Rated thermal current [Ith] is 2.5 A in free air, with operational voltage covering 24...240 V AC and 24...60 V DC. Minimum switching is 5 mA at 17 V, so it'll handle low-level logic signals as well as typical control voltages. The DC-13 power ratings go up to 120 W at 240 V, which is enough for solenoid or brake loads on the same circuit. Compliance covers UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC 60947-5-1, plus the 60335 series for appliance applications. That means it's accepted on both sides of the Atlantic without extra paperwork.

Depth is 29 mm (1.1 in) and width 45 mm (1.8 in) – slim enough to slip into a crowded panel without reframing. Height is just 11 mm (0.4 in). Screw-clamp terminals take a tightening torque of 1.7 N·m. Mechanical durability is 100,000 cycles – that's the life of a typical manual starter in a machine tool or HVAC application. Color is dark grey, which matches the standard TeSys Deca moulding.

Designed as a fault signal auxiliary for GB2CB... circuit breakers or GG fuse 10 A manual starters. One unit per set; no quantity breaks in the package.

Frequently asked questions

What is the color of GVAED101?

Dark grey, matching the TeSys Deca range.

What are the key electrical ratings?

2.5 A thermal current (Ith), operating voltage 24...240 V AC / 24...60 V DC, minimum switching 5 mA at 17 V. DC-13 rating 120 W at 240 V.

What compliance standards does it meet?

UL 60947-4-1, CSA C22.2 No 60947-4-1, IEC 60947-5-1, plus IEC/EN 60335-1 Clause 30.2 and IEC/EN 60335-2-40 Annex JJ.

MPN