Skip to main content
Schneider Electric ILA2T571TB1A0 — Servo Motors with Brake

ILA2T571TB1A0 Schneider Lexium Drive, 0.31 N.m

MPNILA2T571TB1A0
Obsolete

Schneider Electric Lexium ILA2T571TB1A0, AC synchronous servo motor, 57 mm flange, 0.31 N.m nominal torque, 24/48 VDC bus, single-turn encoder.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

ILA2T571TB1A0 — Identification
ParameterValue
Product typeMotion integrated drive
Holding brakeWithout
ILA2T571TB1A0 — Performance
ParameterValue
Nominal torque2.74 lbf.in (0.31 N.m)
Nominal speed5000 rpm 24 V 7000 rpm 48 V
Continuous stall torque2.74 lbf.in (0.31 N.m)
Peak stall torque3.98 lbf.in (0.45 N.m)
Rotor inertia0.095 kg.cm²
ILA2T571TB1A0 — Electrical
ParameterValue
Rated supply voltage (Us)24 V 48 V
PhaseSingle phase
Number of motor poles6
Electrical connectionPrinted circuit board connector
ILA2T571TB1A0 — Feedback
ParameterValue
Feedback typeSingle turn encoder
Speed feedback resolution16384 points/turn
ILA2T571TB1A0 — Mechanical
ParameterValue
Shaft end styleUntapped
Shaft diameter0.4 in (9 mm)
Shaft length0.8 in (20 mm)
Second shaft endWithout second shaft end
Motor flange size2.2 in (57 mm)
Mounting supportFlange
Length5.7 in (145.3 mm)
Number of mounting holes4
Mounting-hole diameter0.2 in (5.2 mm)
Mounting-hole bolt circle diameter2.6 in (66.6 mm)
Centring collar diameter2.0 in (50 mm)
Centring collar depth0.06 in (1.6 mm)
Maximum radial force (Fr)89 N
Maximum axial force (Fa)104 N force pressure) 104 N tensile force)
ILA2T571TB1A0 — Environmental
ParameterValue
IP degree of protectionIP41 shaft bushing: conforming to EN/IEC 60034-5 IP54 total except shaft bushing: conforming to EN/IEC 60034-5
Cooling methodNatural convection

Product details

Sizing the ILA for a 24/48 VDC motion axis

The ILA2T571TB1A0 is the AC synchronous servo member of the Schneider Lexium integrated drive line (ILA short name, Lexium integrated drive range), built around a 57 mm flange and a single-turn encoder for commutation feedback. It draws 7500 mA maximum continuous and peaks at 11000 mA, which fixes the DC-bus sizing: at 24 V the nominal speed is 5000 rpm and climbs to 7000 rpm at 48 V — pick the supply rail first, then the motion profile.

Mechanical fit and shaft interface

Mounting is flange-supported with a 57 mm motor flange, and the shaft end is untapped — couplings or mounted elements need a clamping-hub style fastening rather than a setscrew on the shaft thread. Shaft diameter is 9 mm with a 20 mm shaft length, and the centring collar depth is 1.6 mm — verify the mating pulley or pinion bore and keyway before committing the BOM line. Body length is 145.3 mm, so the cut-out and clearance for the gear-side accessory must accommodate the short-block footprint of the ILA family.

I/O, feedback, and what the drive tells you

Feedback is a single-turn encoder — sufficient for absolute position within one revolution, which simplifies homing on power-up but is not a multi-turn replacement; confirm the application does not require retained position across power cycles. Four signals are available as input or output, so the same physical pin serves either role depending on configuration — plan the wiring diagram with the four-channel budget, not against a fixed direction. Network type is DC and electrical connection is via a printed circuit board connector — the drive is intended to drop onto a mating PCB rather than accept discrete cabling on the motor housing.

Protective functions and ambient envelope

Protection covers output voltage overload, safe torque off, and output short circuit — safe torque off is the functional stop the integrator relies on for guard-door release, not just an overcurrent trip. Cooling is natural convection — no fan to fail in service, but the rated torque holds only if the housing sees unobstructed airflow; inside a sealed cabinet the derating curve on the product drawing applies. Operating altitude is 1000 m without derating, relative humidity 15 to 85 percent non-condensing, vibration resistance 20 m/s² across 10 to 500 Hz, and shock resistance 150 m/s² for 1000 shocks — within the IEC 60068-2 envelope for industrial panels. Bearing service life is rated at 20000 h — the L10 figure rather than an MTBF figure, and is the limit that drives preventive replacement on high-cycle lines.

Standards the integrator has to clear

The ILA2T571TB1A0 is marked CE and listed against IEC 60072-1 for mounting dimensions, EN/IEC 61800-3 for EMC in the second environment, EN 50347 for motor dimensions, and EN/IEC 50178 for power drive systems — the standards the panel builder certifies against rather than a regional UL file. Note the absence of an explicit UL listing in this evidence bundle — for North American UL 508A panel builds, confirm acceptance through the local inspector rather than assuming the CE mark transfers.

Ordering posture for this line

For a tail-spend consolidator, the right play is to put this order code on the preferred-supplier punch-out so the next PO is one-click rather than a one-off requisition — same quoted-to-order economics, lower cost per PO.

Frequently asked questions

What is the listed phase and length for ILA2T571TB1A0?

Phase is single phase and body length is 145.3 mm (5.7 in) on the ILA2T571TB1A0 — figures read straight off the spec sheet for this 57 mm flange variant.

What compliance documentation does Schneider Electric provide for ILA2T571TB1A0?

The ILA2T571TB1A0 carries CE marking and is cited against IEC 60072-1, EN/IEC 61800-3, EN 50347, and EN/IEC 50178. No UL file number appears in this evidence bundle — confirm North American acceptance through the local authority having jurisdiction before panel build.

MPN
ILA2T571TB1A0