Skip to main content
Schneider Electric ILE2T661PB1A8 — Servo Motors

Schneider Electric ILE2T661PB1A8 Lexium integrated drive

MPNILE2T661PB1A8
Obsolete

Schneider Electric, Lexium integrated drive, ILE series brushless DC servo motor with 3-stage worm gearbox, ILE2T661PB1A8, 35 rpm, 115:1 reduction, 24/48 VDC, flange mount, 66 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

ILE2T661PB1A8 — Identification
ParameterValue
Product rangeLexium integrated drive
Product typeMotion integrated drive
ILE2T661PB1A8 — Performance
ParameterValue
Nominal (rated) torque93.8 lbf.in (10.6 N.m) 24 V 93.8 lbf.in (10.6 N.m) 48 V
Nominal output power37 W 24 V 39 W 48 V
Continuous stall torque123.9 lbf.in (14 N.m)
Peak stall torque218.79 lbf.in (24.72 N.m) 24 V 218.79 lbf.in (24.72 N.m) 48 V
Maximum mechanical speed44 rpm
Nominal (rated) speed35 rpm 24 V 35 rpm 48 V
Rotor inertia1980 kg.cm²
ILE2T661PB1A8 — Electrical
ParameterValue
Electrical connection typePrinted circuit board connector
ILE2T661PB1A8 — Feedback & Control
ParameterValue
Speed feedback resolution12 points/turn motor 0.26° gearbox output
ILE2T661PB1A8 — Mechanical
ParameterValue
Holding brakeWithout
Shaft end typeHole
Mounting supportFlange
Maximum radial force (Fr)200 N
Maximum axial force (Fa)80 N
Length9.02 in (229 mm)
ILE2T661PB1A8 — Environmental
ParameterValue
IP protection ratingIP41 shaft bushing: conforming to IEC 60034-5 IP54 total except shaft bushing: conforming to IEC 60034-5

Product details

Drop-in motion axis for low-voltage DC panels

The ILE2T661PB1A8 is the ILE device short within Schneider Electric's Lexium integrated drive range — a brushless DC motor with a 3-stage worm gearbox and a BLDC encoder feedback channel, built for flange mounting on a machine frame rather than panel-side DIN rail. It runs on a single-phase DC bus with supply limits of 18 to 55.2 V, so the same drive accepts a 24 VDC rail or a 48 VDC rail without reconfiguration, and the nominal torque holds at 10.6 N·m on either supply with peak stall torque of 24.72 N·m available for the acceleration transient. Nominal output power is 37 W on 24 V and 39 W on 48 V at 35 rpm, and the integrated 115:1 reduction (3675:32) delivers that speed and torque directly to the output shaft — the gearbox is not an option to add later, it is the mechanical interface of the unit.

Current draw, protection, and the 4 signal lines

Peak current draw is 7000 mA and maximum continuous draw is 5500 mA, which sets the upstream fuse and PSU sizing — a 24 V supply must deliver at least 7 A of peak headroom, and a 48 V supply roughly half that for the same mechanical output. Onboard protection covers safe torque off, output overvoltage, and output short circuit, and the unit exposes 4 signals that can each be configured as input or output, giving a small PLC or motion controller direct control of limit, enable, and status without an intermediate I/O block. Communication runs at 10 or 100 Mbits, so the drive can sit on a standard Ethernet motion bus or be commissioned over a point-to-point link during bench setup.

Mechanical envelope and field-side ratings

Flange size is 66 mm, overall length 229 mm, with a hollow shaft end and no second shaft — the mating gear, pulley, or coupling mounts directly to the gearbox output, and the unit is cooled by natural convection with no fan to fail. The connection side is a printed circuit board connector, so wiring lands on a header rather than a screw terminal block — the panel-side integration is a cable assembly with the mating housing, not a field-wireable plug. Mechanical endurance is rated to 150 m/s² shock (1000 shocks per IEC 60068-2-29) and 20 m/s² vibration across 10 to 500 Hz over 10 cycles per IEC 60068-2-6, with a 9000 h bearing service life and a detent torque of 16.7 N·m that holds position when the drive is unpowered.

Compliance footprint for machine builders

The unit carries the CE mark and is designed to IEC 50347, EN 61800-3:2001 (second environment), IEC 61800-3 Ed 2, IEC 50178, and IEC 60072-1 — the second-environment EMC classification means it is intended for installation in industrial sites with their own supply transformer, not for direct connection to a residential low-voltage network.

Frequently asked questions

What supply voltage does the ILE2T661PB1A8 accept and what current does it draw?

The supply limits are 18 to 55.2 VDC on a single-phase DC bus, so a 24 V or 48 V rail both work. Peak current draw is 7000 mA and maximum continuous is 5500 mA — the upstream PSU and fuse must be sized to the peak, not the continuous figure, for the acceleration transient to clear without a dip.

What output speed and torque does this Lexium integrated drive deliver?

Nominal speed is 35 rpm on both 24 V and 48 V with nominal torque of 10.6 N·m and peak stall torque of 24.72 N·m available on either supply. The 115:1 reduction (3675:32) from the 3-stage worm gearbox is integrated into the unit, so the rated speed and torque are at the gearbox output, not the motor shaft.

What compliance and EMC standards does the ILE2T661PB1A8 meet?

The unit is CE marked and built to IEC 50347, EN 61800-3:2001 second environment, IEC 61800-3 Ed 2, IEC 50178, and IEC 60072-1. The second-environment EMC classification means it is intended for industrial sites with a dedicated supply transformer, not for direct connection to a residential low-voltage network.

MPN
ILE2T661PB1A8