Specifications

JRL36250U31X key specifications
ParameterValue
Control typeToggle
Protection typeOverload protection Short-circuit protection
Product or component typeCircuit breaker
Voltage750 V IEC 60947-2
[Ue] rated operational voltage600 V AC 50/60 Hz IEC 60947-3
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Breaking capacity200 kA 240 V AC 50/60 Hz UL 489 200 kA 480 V AC 50/60 Hz UL 489 100 kA 600 V AC 50/60 Hz UL 489
Line rated current250 A
Breaking capacity codeR
Continuous current rating80 %
[Ics] rated service breaking capacity150 kA 220/240 V AC 50/60 Hz IEC 60947-2 125 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 75 kA 500/525 V AC 50/60 Hz IEC 60947-2 20 kA 690 V AC 50/60 Hz IEC 60947-2
Power wire stripping length1.0 in (25 mm)

All specifications

JRL36250U31X additional specifications
ParameterValue
Network frequency50/60 Hz
Poles3P
Utilisation categoryCategory A
IP degree of protectionFront cover IP40
Communication interfaceModbus
Mounting modeUnit mount lug)
Mounting supportLug
Terminal identifierAL250JD
Electrical connectionLugs, line Lugs, load
Pollution degree3
Operating altitude< 6561.68 ft (2000 m) without derating 5000 m with derating
Depth3.4 in (86 mm)
Width4.09 in (104 mm)
Height7.5 in (191 mm)
StandardsUL CSA NEMA NOM-003-SCFI-2000 IEC 60947-2
CategoryUS10DE201108
AWG gaugeAWG 3/0...350 kcmil aluminium/copper terminals
Quality labelsCE
Trip unit nameMicroLogic 3.2
Number of slots2 auxiliary switch OF plug-in) 1 alarm switch SD plug-in) 1 overcurrent trip switch SDE plug-in) 1 voltage release MN or MX plug-in)
Local signallingReady 1 LED green) Alarm 1 LED 90 % Ir orange) Alarm 1 LED 105 % Ir red) Switched off (OFF) 1 trip indicator green)
Tightening torque221.3 lbf.in (25 N.m) 0.1...0.3 in² (95...185 mm²) (AWG 3/0...350 kcmil)
Trip unit technologyElectronic, standard, MicroLogic 3.2, LI
Suitability for isolationYes IEC 60947-2
Circuit breaker applicationHACR rated
Long time pick-up adjustment range0.25...1 x In
Ambient air temperature for storage-58...185 °F (-50...85 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)
MPN