Skip to main content
Schneider Electric LA1SK10 — Motor Control Accessories

Schneider LA1SK10 Power Add-on Block, 1 NO, 12 A, Obsolete

MPNLA1SK10
Obsolete

Schneider Electric TeSys SK LA1SK10 power add-on block, 1 NO power + 1 NO signalling contact, 12 A at 690 V AC, IP2X, obsolete.

$7.84Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LA1SK10 — Identification
ParameterValue
Product / component typePower add-on block
LA1SK10 — Electrical
ParameterValue
Rated operational voltage (Ue)Signalling circuit 690 V AC Power circuit 690 V AC 50/60 Hz
Pole / contact composition1 NO
LA1SK10 — Cable & Connector
ParameterValue
Terminal connection capacityconnector 1 0.0005...0.009 in² (0.35...6 mm²)flexible with cable end connector 1 0.0008...0.009 in² (0.5...6 mm²)flexible without cable end connector 1 0.002...0.009 in² (1.5...6 mm²)solid connector 2 0.0005...0.002 in² (0.35...1.5 mm²)flexible with cable end connector 2 0.0005...0.004 in² (0.35...2.5 mm²)flexible without cable end connector 2 0.002...0.006 in² (1.5...4 mm²)solid
LA1SK10 — Environmental
ParameterValue
IP protection ratingIP2X VDE 0106
Operating ambient temperature-4...122 °F (-20...50 °C)
Storage ambient temperature-58...158 °F (-50...70 °C)
Operating altitude6561.68 ft (2000 m) without derating
LA1SK10 — Approvals
ParameterValue
Conformance standardsEN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1

Product details

Obsolete — sourcing through independent channels

Schneider Electric has marked the LA1SK10 as obsolete. No direct successor is listed by the manufacturer. Sourcing now runs through independent surplus and broker channels — quantities are lot-specific, confirmed at RFQ against your BOM line.

The LA1SK10 is a TeSys SK power add-on block carrying one normally-open power pole and one normally-open auxiliary signalling contact. It adds a switched power circuit and a status feedback contact to a contactor or starter assembly without expanding the main power pole count. Rated operational current is 12 A in AC-1 duty at 55 °C for the power circuit, and 10 A for the signalling circuit. The conventional free-air thermal current (Ith) matches these figures — the block is sized for continuous current at the stated ambient.

The making capacity is 66 A at 690 V AC — this is the peak inrush the NO power contact can close onto without welding. For a motor load, the AC-3 utilisation category applies; the block is listed for both AC-1 (resistive) and AC-3 (motor) duty. Short-time withstand current (Icw) is 50 A at 55 °C for the power circuit — the block can hold that fault current for the rated duration without damage, coordinating with a 10 A gI fuse on the signalling circuit per VDE 0660. IP2X finger protection per VDE 0106 means the block is touch-safe inside an enclosure but not sealed against moisture — it belongs in a panel, not a washdown zone. Terminals accept flexible wire with ferrule from 0.35 to 6 mm² on the power side, and solid wire up to 4 mm². Tightening torque is 0.8 Nm using a Pozidriv No 1 bit — consistent with standard terminal block practice in a control panel.

This covers acceptance in most industrial control panels globally. Altitude rating is 2000 m without derating — above that, dielectric strength and thermal dissipation need a correction factor.

Frequently asked questions

What are the key ratings of the LA1SK10?

The LA1SK10 is a power add-on block with 1 NO power contact rated 12 A at 690 V AC (AC-1) and 1 NO signalling contact rated 10 A. Making capacity is 66 A at 690 V AC. Short-time withstand current is 50 A. IP2X finger protection. Terminals accept 0.35–6 mm² flexible wire.

MPN