Schneider Electric LA1LB031 TeSys Auxiliary Contact Block

MPNLA1LB031
Active

Schneider Electric TeSys LA1LB031 auxiliary contact block, 2 NO instantaneous contacts, screw-clamp terminals, 10 A conventional free air thermal current, 690 V rated insulation voltage.

$81.84Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LA1LB031 — Identification
ParameterValue
Product / component typeAuxiliary contact
Product rangeTeSys
LA1LB031 — Cable & Connector
ParameterValue
Terminal connection capacity2 screw clamps terminals 0.002 in² (1 mm²) 2 screw clamps terminals 0.004 in² (2.5 mm²)
LA1LB031 — Other specifications
ParameterValue
Making capacity1500 VA 48 V AC AC-15) 220 W 440 V DC DC-13) 260 W 220 V DC DC-13) 3500 VA 110...127 V AC AC-15) 400 W 110 V DC DC-13) 6000 VA 220...240 V AC AC-15) 700 W 48 V DC DC-13) 7000 VA 440 V AC AC-15) 7500 VA 380...415 V AC AC-15) 800 W 24 V DC DC-13)
Device short nameLA1LB
Auxiliary contacts typeInstantaneous 2 NO) control knob in any position other than auto
Switching capacity in0.6 VA >= 17 V 0.01 A
Rated operational power in120 W 24 V DC-13 1000000 cycles 150 W 48 V DC-13 1500000 cycles 28 W 440 V DC-13 1500000 cycles 33 W 220 V DC-13 1500000 cycles 38 W 110 V DC-13 1500000 cycles 61 W 440 V DC-13 1000000 cycles 68 W 220 V DC-13 1000000 cycles 70 W 24 V DC-13 1500000 cycles 75 W 110 V DC-13 1000000 cycles 90 W 48 V DC-13 1000000 cycles
Voltage690 V IEC 60947-5-1
[Ith] conventional free air thermal current10 A

Product details

Auxiliary contact block for TeSys contactors

The LA1LB031 is a TeSys auxiliary contact block from Schneider Electric, adding two normally-open instantaneous contacts to a contactor or starter assembly. It mounts directly onto the front of the contactor, expanding the control circuit without additional panel wiring. Rated for 10 A conventional free air thermal current (Ith) and 690 V insulation voltage per IEC 60947-5-1, this block handles typical control-circuit voltages from 24 V DC up to 440 V AC/DC across the making-capacity table.

Termination and wiring constraints

Two screw-clamp terminals accept 1 mm² to 2.5 mm² conductors — the smaller gauge for signal-level wiring, the larger for the full 10 A thermal rating. The clamping mechanism holds stranded or solid wire without ferrules, though ferruled ends simplify insertion in tight panel layouts. The 2 NO configuration is instantaneous, meaning the contacts follow the contactor armature position without delay — no timing or sequencing built into the block. This suits interlocking, status feedback, or control-circuit extension where the auxiliary mirrors the main pole state.

Making capacity spans 1500 VA at 48 V AC (AC-15) up to 7500 VA at 380-415 V AC (AC-15), with corresponding DC-13 ratings from 220 W at 440 V DC to 800 W at 24 V DC. These values define the maximum inrush the contacts can close onto — relevant when switching solenoid loads or small contactor coils. Rated operational power in VA and W is also specified at 1 million or 1.5 million cycles depending on the voltage and duty — the 440 V DC-13 rating at 28 W for 1.5 million cycles is the endurance floor; the 24 V DC-13 rating at 120 W for 1 million cycles is the power ceiling.

Frequently asked questions

What is the LA1LB031 used for?

It is an auxiliary contact block that adds two normally-open instantaneous contacts to a TeSys contactor or starter.

What wire sizes fit the LA1LB031 terminals?

The screw-clamp terminals accept 1 mm² to 2.5 mm² conductors. For the full 10 A thermal rating, use 2.5 mm²; for signal-level control wiring, 1 mm² is sufficient.