Schneider Electric LC1BL31U22

Schneider Electric LC1BL31U22

MPNLC1BL31U22
Active

bar-mounted contactor - TeSys LC1-BL -1P- AC-1 1000 V 800 A - coil 240 VAC

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LC1BL31U22 key specifications
ParameterValue
Coil typeStandard
Control circuit typeAC
Auxiliary contacts typeInstantaneous 2 NO + 2 NC
Product or component typeContactor
Coil voltage240 V AC 50...400 Hz
Voltage1000 V - power circuit IEC 60158-1 1000 V - power circuit IEC 60947-4 1500 V - power circuit VDE 0110 group C
Control circuit voltage limitsDrop-out: 0.3...0.5 Uc Operational: 0.85...1.1 Uc
[Ue] rated operational voltagePower circuit <= 1000 V AC 50/60 Hz
Breaking capacity10000 A at 440 V for power circuit conforming to IEC 60158-1 10000 A at 440 V for power circuit conforming to IEC 60947-4 4000 A at 1000 V for power circuit conforming to IEC 60158-1 4000 A at 1000 V for power circuit conforming to IEC 60947-4 8000 A at 660...690 V for power circuit conforming to IEC 60158-1 8000 A at 660...690 V for power circuit conforming to IEC 60947-4 9000 A at 500 V for power circuit conforming to IEC 60158-1 9000 A at 500 V for power circuit conforming to IEC 60947-4
[Ie] rated operational current800 A (at <104 °F (40 °C)) AC AC-1 for power circuit
[Ith] conventional free air thermal current800 A (at 104 °F (40 °C)) for power circuit
Inrush power in620 VA

All specifications

LC1BL31U22 additional specifications
ParameterValue
Power dissipation per pole115 W AC-1 - Ith 800 A
Rated operational power in200 W 500 V AC 1000000 cycles - control circuit 230 W 440 V AC 1000000 cycles - control circuit 250 W 110 V AC 1000000 cycles - control circuit 250 W 220 V AC 1000000 cycles - control circuit
Hold-in power consumption in10 VA
Poles description1P
Pole contact composition1 NO
Utilisation categoryAC-1
Operating altitude9842.52 ft (3000 m) without derating
Depth18.7 in (475 mm)
Width18.7 in (475 mm)
Height19.1 in (486 mm)
Mechanical durability1200000 cycles
StandardsVDE 0660 IEC 60947-4 IEC 60158-1 NF C 63-110 BS 5424
RangeTeSys
Category18402-WORLD SERVICE PARTS(CONTROL ACCESS)
Operating time100...150 ms closing 20...40 ms opening
Protective coverWith
Average impedance0.18 mOhm - Ith 800 A 50 Hz for power circuit
Device short nameLC1BL
Tightening torquePower circuit 185.9 lbf.in (21 N.m) bars
Protective treatmentTC TH
Contactor applicationMotor-heating-lighting
Associated fuse rating1000 A gI at 800 A aM at 800 A gI at <= 440 V for power circuit
Maximum operating rate120 cyc/h 131 °F (55 °C)
Irms rated making capacity10000 A at 1000 V AC for power circuit conforming to IEC 60158-1 10000 A at 1000 V AC for power circuit conforming to IEC 60947-4
Auxiliary contact composition2 NO + 2 NC
Ambient air temperature for storage-76...176 °F (-60...80 °C)
Ambient air temperature for operation23...131 °F (-5...55 °C)
MPN
LC1BL31U22