Schneider Electric LC1BL33P22
MPNLC1BL33P22
Active
bar-mounted contactor - TeSys LC1-BL - 3 poles - AC-3 440V 750 A - coil 230V AC
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
| Parameter | Value |
|---|---|
| Coil type | Standard |
| Control circuit type | AC |
| Product or component type | Contactor |
| Coil voltage | 230 V AC 50...400 Hz |
| Voltage | 1000 V - for power circuit conforming to IEC 60158-1 1000 V - for power circuit conforming to IEC 60947-4 1500 V - for power circuit conforming to VDE 0110 group C |
| Control circuit voltage limits | Drop-out: 0.3...0.5 Uc at 50...400 Hz Operational: 0.85...1.1 Uc at 50...400 Hz |
| [Ue] rated operational voltage | Power circuit: <= 1000 V AC 50/60 Hz |
| Breaking capacity | 10000 A at 440 V for power circuit conforming to IEC 60158-1 10000 A at 440 V for power circuit conforming to IEC 60947-4 4000 A at 1000 V for power circuit conforming to IEC 60158-1 4000 A at 1000 V for power circuit conforming to IEC 60947-4 8000 A at 660...690 V for power circuit conforming to IEC 60158-1 8000 A at 660...690 V for power circuit conforming to IEC 60947-4 9000 A at 500 V for power circuit conforming to IEC 60158-1 9000 A at 500 V for power circuit conforming to IEC 60947-4 |
| [Ie] rated operational current | 800 A (at 750 A (at <55 °C) AC AC-3 for power circuit |
| [Ith] conventional free air thermal current | 800 A (at 40 °C) for power circuit |
| Motor power | 220 kW at 220...230 V AC 50/60 Hz 400 kW at 380...400 V AC 50/60 Hz 425 kW at 415 V AC 50/60 Hz 450 kW at 440 V AC 50/60 Hz 500 kW at 500 V AC 50/60 Hz 530 kW at 1000 V AC 50/60 Hz 560 kW at 660...690 V AC 50/60 Hz |
| Inrush power in | 1300 VA |
All specifications
| Parameter | Value |
|---|---|
| Power dissipation per pole | 115 W AC-1 - Ith 800 A 88 W AC-3 - Ith 800 A |
| Hold-in power consumption in | 31 VA 50/60 Hz |
| Poles description | 3P |
| Pole contact composition | 3 NO |
| Utilisation category | AC-1 AC-3 |
| Mounting mode | Fixed |
| Mounting support | Notched mounting rails Bar support bracket |
| Operating altitude | 3000 m without derating |
| Depth | 475 mm |
| Width | 570 mm |
| Height | 486 mm |
| Mechanical durability | 1200000 cycles |
| Standards | BS 5424 IEC 60158-1 NF C 63-110 IEC 60947-4 VDE 0660 |
| Range | TeSys |
| Operating time | 100...150 ms closing 50...100 ms opening |
| Average impedance | 0.18 mOhm - Ith 800 A 50 Hz for power circuit |
| Device short name | LC1BL |
| Tightening torque | Power circuit: 21 N.m - on bars |
| Protective treatment | TC TH |
| Contactor application | Motor-heating-lighting |
| Associated fuse rating | 1000 A gI at 800 A aM at 800 A gI at <= 440 V for power circuit |
| Maximum operating rate | 120 cyc/h 55 °C |
| Irms rated making capacity | 10000 A at 1000 V AC for power circuit conforming to IEC 60158-1 10000 A at 1000 V AC for power circuit conforming to IEC 60947-4 |
| Auxiliary contact composition | 2 NO + 2 NC |
| Ambient air temperature for storage | -60...80 °C |
| Ambient air temperature for operation | -5...55 °C |
MPN
LC1BL33P22