Schneider Electric LC1BP32U31
MPNLC1BP32U31
Obsolete
bar-mounted contactor - TeSys LC1-BP -2 poles - AC-1 1000V 2000 A - coil 240 VAC
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
| Parameter | Value |
|---|---|
| Coil type | Standard |
| Control circuit type | AC |
| Auxiliary contacts type | Instantaneous 3 NO + 1 NC |
| Product or component type | Contactor |
| Coil voltage | 240 V AC 50...400 Hz |
| Voltage | 1000 V - power circuit IEC 60158-1 1000 V - power circuit IEC 60947-4 1500 V - power circuit VDE 0110 group C |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc Drop-out: 0.35...0.5 Uc |
| [Ue] rated operational voltage | Power circuit <= 1000 V AC 50/60 Hz |
| Breaking capacity | 12000 A at 500 V for power circuit conforming to IEC 60158-1 12000 A at 500 V for power circuit conforming to IEC 60947-4 15000 A at 440 V for power circuit conforming to IEC 60158-1 15000 A at 440 V for power circuit conforming to IEC 60947-4 5000 A at 1000 V for power circuit conforming to IEC 60158-1 5000 A at 1000 V for power circuit conforming to IEC 60947-4 9000 A at 660...690 V for power circuit conforming to IEC 60158-1 9000 A at 660...690 V for power circuit conforming to IEC 60947-4 |
| [Ie] rated operational current | 2000 A (at <104 °F (40 °C)) AC AC-1 for power circuit |
| [Ith] conventional free air thermal current | 2000 A (at 104 °F (40 °C)) for power circuit |
| Inrush power in | 1000 VA |
All specifications
| Parameter | Value |
|---|---|
| Power dissipation per pole | 520 W AC-1 - Ith 2000 A |
| Rated operational power in | 200 W 500 V AC 1000000 cycles - control circuit 230 W 440 V AC 1000000 cycles - control circuit 250 W 110 V AC 1000000 cycles - control circuit 250 W 220 V AC 1000000 cycles - control circuit |
| Hold-in power consumption in | 20 VA |
| Poles description | 2P |
| Pole contact composition | 2 NO |
| Utilisation category | AC-1 |
| Connections - terminals | Power circuit bars 3 x 100 x 5 mm |
| Operating altitude | 9842.52 ft (3000 m) without derating |
| Depth | 22.4 in (570 mm) |
| Width | 18.7 in (475 mm) |
| Height | 19.7 in (500 mm) |
| Mechanical durability | 1200000 cycles |
| Standards | BS 5424 IEC 60158-1 IEC 60947-4 VDE 0660 NF C 63-110 |
| Range | TeSys |
| Category | 18402-WORLD SERVICE PARTS(CONTROL ACCESS) |
| Operating time | 100...150 ms closing 20...40 ms opening |
| Protective cover | With |
| Average impedance | 0.13 mOhm - Ith 2000 A 50 Hz for power circuit |
| Device short name | LC1BP |
| Tightening torque | Power circuit 309.8 lbf.in (35 N.m) bars |
| Protective treatment | TC TH |
| Contactor application | Motor-heating-lighting |
| Associated fuse rating | 1600 A aM at 2000 A gI at <= 440 V for power circuit |
| Maximum operating rate | 120 cyc/h 131 °F (55 °C) |
| Irms rated making capacity | 15000 A at 1000 V AC for power circuit conforming to IEC 60158-1 15000 A at 1000 V AC for power circuit conforming to IEC 60947-4 |
| Auxiliary contact composition | 3 NO + 1 NC |
| Ambient air temperature for storage | -76...176 °F (-60...80 °C) |
| Ambient air temperature for operation | 23...131 °F (-5...55 °C) |
MPN
LC1BP32U31