Schneider Electric LC1BR33ED22
MPNLC1BR33ED22
Obsolete
bar-mountedcontactor-TeSysLC1-BR-3P-AC-31000V2750A-coil48VDC
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
| Parameter | Value |
|---|---|
| Coil type | Standard |
| Control circuit type | DC |
| Auxiliary contacts type | type instantaneous 2 NO + 2 NC |
| Product or component type | Contactor |
| Coil voltage | 48 V DC |
| Voltage | 1000 V - for power circuit conforming to IEC 60158-1 1000 V - for power circuit conforming to IEC 60947-4 1500 V - for power circuit conforming to VDE 0110 group C |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc Drop-out: 0.4...0.5 Uc |
| [Ue] rated operational voltage | Power circuit: <= 1000 V AC 50/60 Hz |
| Breaking capacity | 11000 A at 660...690 V for power circuit conforming to IEC 60158-1 11000 A at 660...690 V for power circuit conforming to IEC 60947-4 15000 A at 500 V for power circuit conforming to IEC 60158-1 15000 A at 500 V for power circuit conforming to IEC 60947-4 18000 A at 440 V for power circuit conforming to IEC 60158-1 18000 A at 440 V for power circuit conforming to IEC 60947-4 6000 A at 1000 V for power circuit conforming to IEC 60158-1 6000 A at 1000 V for power circuit conforming to IEC 60947-4 |
| [Ie] rated operational current | 2750 A (at 1800 A (at <40 °C) AC AC-3 for power circuit |
| [Ith] conventional free air thermal current | 2750 A (at 40 °C) for power circuit |
| Motor power | 500 kW at 220...230 V AC 50/60 Hz 750 kW at 1000 V AC 50/60 Hz 900 kW at 380...400 V AC 50/60 Hz 900 kW at 415 V AC 50/60 Hz 900 kW at 440 V AC 50/60 Hz 900 kW at 500 V AC 50/60 Hz 900 kW at 660...690 V AC 50/60 Hz |
All specifications
| Parameter | Value |
|---|---|
| Inrush power in | 1100 W |
| Power dissipation per pole | 680 W AC-1 - Ith 2750 A |
| Rated operational power in | 200 W at 500 V AC - electrical durability: 1000000 cycles - for control circuit 230 W at 440 V AC - electrical durability: 1000000 cycles - for control circuit 250 W at 110 V AC - electrical durability: 1000000 cycles - for control circuit 250 W at 220 V AC - electrical durability: 1000000 cycles - for control circuit |
| Hold-in power consumption in | 31 W |
| Poles description | 3P |
| Pole contact composition | 3 NO |
| Utilisation category | AC-3 AC-1 |
| Connections - terminals | Power circuit: bars 4 x - busbar cross section: 100 x 5 mm |
| Operating altitude | 3000 m without derating |
| Depth | 915 mm |
| Width | 475 mm |
| Height | 555 mm |
| Mechanical durability | 1200000 cycles |
| Standards | IEC 60947-4 NF C 63-110 IEC 60158-1 BS 5424 VDE 0660 |
| Range | TeSys |
| Operating time | 100...150 ms closing 20...40 ms opening |
| Protective cover | With |
| Average impedance | 0.09 mOhm - Ith 2750 A 50 Hz for power circuit |
| Device short name | LC1BR |
| Tightening torque | Power circuit: 35 N.m - on bars |
| Protective treatment | TC TH |
| Contactor application | Motor-heating-lighting |
| Associated fuse rating | 2000 A aM at 2400 A gI at <= 440 V for power circuit |
| Maximum operating rate | 120 cyc/h 55 °C |
| Irms rated making capacity | 18000 A at 1000 V AC for power circuit conforming to IEC 60158-1 18000 A at 1000 V AC for power circuit conforming to IEC 60947-4 |
| Auxiliary contact composition | 2 NO + 2 NC |
| Ambient air temperature for storage | -60...80 °C |
| Ambient air temperature for operation | -5...55 °C |
MPN
LC1BR33ED22