Schneider Electric LC1D400086U6

Schneider Electric LC1D400086U6

MPNLC1D400086U6
Obsolete

TeSys Deca contactor, 4P(2 NO + 2 NC), AC-1, <= 440V, 60 A, 240V AC 60 Hz coil

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1D400086U6 key specifications
ParameterValue
Range of productTeSys Deca
Control circuit typeAC 60 Hz
Product or component typeContactor
Climatic withstandIACS E10 exposure to damp heat
Coil voltage240 V AC 60 Hz
VoltagePower circuit 600 V CSA Power circuit 600 V UL Power circuit 690 V IEC 60947-4-1
Control circuit voltage limits0.85...1.1 Uc (-40...140 °F (-40...60 °C)):operational AC 60 Hz 0.3...0.6 Uc (-40...158 °F (-40...70 °C)):drop-out AC 60 Hz 1...1.1 Uc (140...158 °F (60...70 °C)):operational AC 60 Hz
[Ue] rated operational voltagePower circuit Power circuit <= 300 V DC
[Uimp] rated impulse withstand voltage6 kV IEC 60947
[Icw] rated short-time withstand current320 A 104 °F (40 °C) - 10 s for power circuit 720 A 104 °F (40 °C) - 1 s for power circuit 72 A 104 °F (40 °C) - 10 min for power circuit 165 A 104 °F (40 °C) - 1 min for power circuit
Breaking capacity800 A at 440 V for power circuit conforming to IEC 60947
[Ie] rated operational current60 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit

All specifications

LC1D400086U6 additional specifications
ParameterValue
[Ith] conventional free air thermal current60 A (at 140 °F (60 °C)) for power circuit
Inrush power in140 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
Power dissipation per pole5.4 W AC-1
Hold-in power consumption in13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
Poles description4P
Pole contact composition2 NO + 2 NC
Utilisation categoryAC-1
IP degree of protectionIP20 front face IEC 60529
Mounting supportRail Plate
Connections - terminalsControl circuit: lugs-ring terminals - external diameter: 0.3 in (8 mm) Power circuit: lugs-ring terminals - external diameter: 0.6 in (16.5 mm)
Pollution degree3
Operating altitude0...9842.52 ft (0...3000 m)
Depth4.9 in (125 mm)
Width3.3 in (85 mm)
Height5 in (127 mm)
Electrical durability1.4 Mcycles 60 A AC-1 <= 440 V
Mechanical durability6 Mcycles
StandardsCSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
RangeTeSys
Category22357-CTR,TESYS D,OPEN,40-65A AC
Operating time4...19 ms opening 12...26 ms closing
Coil technologyWithout built-in suppressor module
Fire resistance1562 °F (850 °C) IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Heat dissipation4...5 W at 60 Hz
Protective coverWithout
Average impedance1.5 mOhm - Ith 60 A 50 Hz for power circuit
Device short nameLC1D
Tightening torqueControl circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 22.1 lbf.in (2.5 N.m) lugs-ring terminals hexagonal 0.4 in (10 mm) M6
Compatibility codeLC1D
Overvoltage categoryIII
Protective treatmentTHIEC 60068-2-30
Contactor applicationResistive load
Mechanical robustnessShocks contactor open 8 Gn for 11 ms) Shocks contactor closed 10 Gn for 11 ms) Vibrations contactor opened 2 Gn, 5...300 Hz) Vibrations contactor closed 4 Gn, 5...300 Hz)
Associated fuse rating80 A gG at 80 A gG at <= 690 V coordination type 2 for power circuit
Safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms rated making capacity800 A at 440 V for power circuit conforming to IEC 60947
Permissible ambient air temperature around the device-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating
MPN
LC1D400086U6