Schneider Electric LC1D65008FE7
MPNLC1D65008FE7
Obsolete
Contactor, TeSys Deca, 4P(2NO+2NC),AC-1, <=440V, 80 A 115V AC 50/60Hz coil, screw clamp terminal
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
| Parameter | Value |
|---|---|
| Range of product | TeSys Deca |
| Control circuit type | AC at 50/60 Hz |
| Product or component type | Contactor |
| Climatic withstand | conforming to IACS E10 exposure to damp heat |
| Coil voltage | 115 V AC 50/60 Hz |
| Voltage | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 |
| Control circuit voltage limits | 0.3...0.6 Uc (-40...55 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40...55 °C):operational AC 50 Hz 0.85...1.1 Uc (-40...55 °C):operational AC 60 Hz |
| [Ue] rated operational voltage | Power circuit: Power circuit: <= 300 V DC |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 640 A 40 °C - 10 s for power circuit 900 A 40 °C - 1 s for power circuit 110 A 40 °C - 10 min for power circuit 260 A 40 °C - 1 min for power circuit |
| Breaking capacity | 1000 A at 440 V for power circuit conforming to IEC 60947 |
| [Ie] rated operational current | 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
All specifications
| Parameter | Value |
|---|---|
| [Ith] conventional free air thermal current | 80 A (at 60 °C) for power circuit |
| Inrush power in | 245 VA 60 Hz cos phi 0.75 (at 20 °C) 245 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Power dissipation per pole | 9.6 W AC-1 |
| Hold-in power consumption in | 13 VA 60 Hz cos phi 0.3 (at 20 °C) 15 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Poles description | 4P |
| Pole contact composition | 2 NO + 2 NC |
| Utilisation category | AC-1 |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Mounting support | Plate Rail |
| Connections - terminals | Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid without cable end Power circuit: connector 1 2.5...25 mm² - cable stiffness: flexible without cable end Power circuit: connector 2 2.5...16 mm² - cable stiffness: flexible without cable end Power circuit: connector 1 2.5...25 mm² - cable stiffness: flexible with cable end Power circuit: connector 2 2.5...10 mm² - cable stiffness: flexible with cable end Power circuit: connector 1 2.5...25 mm² - cable stiffness: solid without cable end Power circuit: connector 2 2.5...16 mm² - cable stiffness: solid without cable end |
| Pollution degree | 3 |
| Operating altitude | 0...3000 m |
| Depth | 125 mm |
| Width | 85 mm |
| Height | 127 mm |
| Product weight | 1.45 kg |
| Electrical durability | 1.5 Mcycles 80 A AC-1 at Ue <= 440 V |
| Mechanical durability | 6 Mcycles |
| Standards | EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 |
| Range | TeSys |
| Operating time | 4...19 ms opening 12...26 ms closing |
| Coil technology | Without built-in suppressor module |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Heat dissipation | 4...5 W at 50/60 Hz |
| Protective cover | Without |
| Average impedance | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
| Device short name | LC1D |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on screw clamp terminals - cable 25...35 mm² hexagonal screw head 4 mm Power circuit: 5 N.m - on screw clamp terminals - cable 1...25 mm² hexagonal screw head 4 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Compatibility code | LC1D |
| Overvoltage category | III |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Contactor application | Resistive load |
| Mechanical robustness | Shocks contactor open (8 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) |
| Associated fuse rating | 125 A gG at 125 A gG at <= 690 V coordination type 2 for power circuit |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Irms rated making capacity | 1000 A at 440 V for power circuit conforming to IEC 60947 |
| Permissible ambient air temperature around the device | -40...60 °C 60...70 °C with derating |
MPN