Skip to main content
Schneider Electric LC1D80004N5

Schneider LC1D80004N5 TeSys Deca 4-Pole Contactor, Mature

MPNLC1D80004N5
Obsolete

Schneider Electric TeSys Deca series, LC1D80004N5, 4-pole contactor, AC control, 125mm depth, mature lifecycle.

$705.00Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LC1D80004N5 key specifications
ParameterValue
Range of productTeSys Deca
Control circuit typeAC 50 Hz
Product or component typeContactor
Climatic withstandIACS E10 exposure to damp heat
Coil voltage415 V AC 50 Hz
VoltagePower circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1
Control circuit voltage limits0.3...0.6 Uc (-40...158 °F (-40...70 °C)):drop-out AC 50 Hz 0.85...1.1 Uc (-40...131 °F (-40...55 °C)):operational AC 50 Hz 1...1.1 Uc (131...158 °F (55...70 °C)):operational AC 50 Hz
[Ue] rated operational voltagePower circuit Power circuit <= 690 V AC
[Uimp] rated impulse withstand voltage8 kV IEC 60947
[Icw] rated short-time withstand current640 A 104 °F (40 °C) - 10 s for power circuit 990 A 104 °F (40 °C) - 1 s for power circuit 135 A 104 °F (40 °C) - 10 min for power circuit 320 A 104 °F (40 °C) - 1 min for power circuit
Breaking capacity1100 A at 440 V for power circuit conforming to IEC 60947
[Ie] rated operational current125 A (at 80 A (at 80 A (at 55 A (at <140 °F (60 °C)) at <= 400 V AC AC-4 for power circuit

All specifications

LC1D80004N5 additional specifications
ParameterValue
[Ith] conventional free air thermal current125 A (at 140 °F (60 °C)) for power circuit
Motor power22 kW at 220...230 V AC 50/60 Hz 37 kW at 380...400 V AC 50/60 Hz 45 kW at 660...690 V AC 50/60 Hz 55 kW at 500 V AC 50/60 Hz 45 kW at 415...440 V AC 50/60 Hz
Inrush power in200 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Power dissipation per pole12.5 W AC-1
Hold-in power consumption in20 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Poles description4P
Pole contact composition4 NO
Utilisation categoryAC-1
IP degree of protectionIP20 front face IEC 60529
Mounting supportPlate Rail
Connections - terminalsControl circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end Power circuit: connector 1 0.006...0.08 in² (4...50 mm²) - cable stiffness: flexible without cable end Power circuit: connector 2 0.006...0.04 in² (4...25 mm²) - cable stiffness: flexible without cable end Power circuit: connector 1 0.006...0.08 in² (4...50 mm²) - cable stiffness: flexible with cable end Power circuit: connector 2 0.006...0.02 in² (4...16 mm²) - cable stiffness: flexible with cable end Power circuit: connector 1 0.006...0.08 in² (4...50 mm²) - cable stiffness: solid without cable end Power circuit: connector 2 0.006...0.04 in² (4...25 mm²) - cable stiffness: solid without cable end
Pollution degree3
Operating altitude0...9842.52 ft (0...3000 m)
Depth4.9 in (125 mm)
Width3.8 in (96 mm)
Height5 in (127 mm)
Electrical durability0.8 Mcycles 125 A AC-1 <= 440 V
Mechanical durability10 Mcycles
StandardsEN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 CSA C22.2 No 14 UL 60947-4-1 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ IEC 60335-1:Clause 30.2
RangeTeSys
CategoryUS10I1222359
Operating time20...35 ms closing 6...20 ms opening
Coil technologyWithout built-in suppressor module
Fire resistance1562 °F (850 °C) IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Heat dissipation6...10 W at 50 Hz
Protective coverWithout
Average impedance0.8 mOhm - Ith 125 A 50 Hz for power circuit
Device short nameLC1D
Tightening torqueControl circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm) Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
Compatibility codeLC1D
Overvoltage categoryIII
Protective treatmentTHIEC 60068-2-30
Contactor applicationResistive load
Mechanical robustnessVibrations contactor open 2 Gn, 5...300 Hz) Shocks contactor open 8 Gn for 11 ms) Vibrations contactor closed 3 Gn, 5...300 Hz) Shocks contactor closed 10 Gn for 11 ms)
Associated fuse rating200 A gG at 160 A gG at <= 690 V coordination type 2 for power circuit
Maximum operating rate3600 cyc/h at 60 °C
Safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms rated making capacity1100 A at 440 V for power circuit conforming to IEC 60947
Permissible ambient air temperature around the device-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating

Product details

Compliance documentation on record

The contactor holds approvals under IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 14, plus the heat-resistance clauses of IEC 60335-2-40 and IEC 60335-1 clause 30.2. That gives you a solid compliance package for UL and CE-marked panels without hunting for separate certificates.

Physical and mounting notes

Mounts on plate or DIN rail. Contact configuration is 4 NO (normally open). The power circuit accepts cable up to 50 mm² flexible with ferrule, tightening torque 12 N·m. Coil is AC 50 Hz without built-in suppression – you'll need an external RC snubber or varistor if switching inductive control loads.

Frequently asked questions

What compliance documentation does Schneider provide for this contactor?

The LC1D80004N5 is certified to IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 14, and meets IEC 60335-2-40 Annex JJ and IEC 60335-1 Clause 30.2 for fire resistance.

What is the depth of the LC1D80004N5?

The depth is 4.9 in (125 mm).

What series is the LC1D80004N5 from?

It belongs to the TeSys and TeSys Deca ranges from Schneider Electric.

MPN