Skip to main content
Schneider Electric LC1E200B5

Schneider LC1E200B5 Contactor, Easy TeSys, 55-110 kW

MPNLC1E200B5
Obsolete

Schneider Electric Easy TeSys LC1E200B5 3-pole contactor, 55...110 kW motor power, 24 V AC 50 Hz coil, 181 mm depth.

$543.00Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LC1E200B5 key specifications
ParameterValue
Range of productEasy TeSys Control
Control circuit typeAC at 50 Hz
Product or component typeContactor
Coil voltage24 V AC 50 Hz
Voltage690 V conforming to IEC 60947-4-1
Control circuit voltage limits0.85...1.1 Uc (-5...55 °C):operational 50 Hz 0.35...0.55 Uc (-5...55 °C):drop-out 50 Hz
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV coil not connected to the power circuit conforming to IEC 60947
[Icw] rated short-time withstand current1500 A 40 °C - 10 s for power circuit
Breaking capacity1600 A at 440 V for power circuit conforming to IEC 60947
[Ie] rated operational current200 A (at 175 A (at 250 A (at <40 °C) at <= 440 V AC AC-1 for power circuit
[Ith] conventional free air thermal current250 A (at 40 °C) for power circuit

All specifications

LC1E200B5 additional specifications
ParameterValue
Motor power55 kW at 220/230 V AC 50/60 Hz 90 kW at 380/400 V AC 50/60 Hz 100 kW at 415/440 V AC 50/60 Hz 110 kW at 500 V AC 50/60 Hz 110 kW at 660/690 V AC 50/60 Hz 110 kW at 660...690 V AC 50/60 Hz
Inrush power in805 VA 50 Hz cos phi 0.3 (at 20 °C) 970 VA 60 Hz cos phi 0.3 (at 20 °C)
Power dissipation per pole13 W AC-3 21 W AC-1
Hold-in power consumption in55 VA 50 Hz cos phi 0.3 (at 20 °C) 66 VA 60 Hz cos phi 0.3 (at 20 °C)
Poles description3P
Pole contact composition3 NO
Utilisation categoryAC-3 AC-3e AC-1
IP degree of protectionIP2X conforming to IEC 60529
Mounting supportPlate
Connections - terminalsPower circuit: cable with lug 1 1...4 mm² - external diameter: 150 mm - cable stiffness: flexible without cable end Power circuit: bars 2 1...4 mm² - cable stiffness: flexible without cable end - busbar cross section: 3 x 25 mm Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - external diameter: 150 mm - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid without cable end - busbar cross section: 3 x 25 mm
Pollution degree3
Operating altitude3000 m without derating
Depth181 mm
Width168.5 mm
Height174 mm
Product weight4.6 kg
Electrical durability500000 cycles AC-3 200000 cycles AC-1
Mechanical durability5000000 cycles
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 GB/T 14048.1 GB/T 14048.4
RangeEasy TeSys
Operating time20...35 ms on closing 7...15 ms on opening
Fire resistance850 °C conforming to IEC 60695-2-1
Heat dissipation18...24 W for control circuit
Average impedance0.33 mOhm - Ith 250 A 50 Hz for power circuit
Device short nameLC1E
Tightening torqueControl circuit: 1.2 N.m Power circuit: 18 N.m
Overvoltage categoryIII
Protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Contactor applicationMotor control Resistive load
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Associated fuse rating315 A gG at <= 690 V coordination type 1 for power circuit
Maximum operating rate1200 cyc/h 55 °C
Irms rated making capacity2000 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Auxiliary contact compositionWithout
Permissible ambient air temperature around the device-20...70 °C at Uc -60...80 °C storage -5...55 °C operation

Product details

Key ratings in context

The LC1E200B5: Motor power varies by supply voltage: 55 kW at 230 V, 90 kW at 400 V, 100 kW at 415/440 V, and 110 kW at both 500 V and 660/690 V. Use the AC-3 electrical durability of 500,000 cycles for motor-duty life estimation; mechanical durability is 5 million cycles. The contactor is rated AC-3, AC-3e, and AC-1. The contactor ships without auxiliary contacts (: composition = Without). No auxiliary block is included or fitted; order separately if needed. Protective treatment is TH conforming to IEC 60068-2-30, and the part meets IP2X per IEC 60529.

Frequently asked questions

What are the motor power ratings for this contactor?

Motor power ranges from 55 kW at 220/230 V AC up to 110 kW at 660/690 V AC, with intermediate ratings of 90 kW at 380/400 V, 100 kW at 415/440 V, and 110 kW at 500 V.

What is the depth of the LC1E200B5?

The depth is 181 mm.

What compliance standards does this contactor meet?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, GB/T 14048.1, and GB/T 14048.4. Protective treatment is TH conforming to IEC 60068-2-30, and IP degree is IP2X per IEC 60529.

MPN
LC1E200B5