Schneider Electric LC1E500N7
MPNLC1E500N7
Obsolete
Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,500A/400A,415V AC coil
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
| Parameter | Value |
|---|---|
| Range of product | Easy TeSys Control |
| Control circuit type | AC at 50/60 Hz |
| Product or component type | Contactor |
| Coil voltage | 415 V AC 50/60 Hz |
| Voltage | 690 V conforming to IEC 60947-4-1 |
| Control circuit voltage limits | 0.85...1.1 Uc (-5...55 °C):operational 50/60 Hz 0.35...0.5 Uc (-5...55 °C):drop-out 50/60 Hz |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 8 kV coil not connected to the power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 4200 A 40 °C - 10 s for power circuit |
| Breaking capacity | 4000 A at 440 V for power circuit conforming to IEC 60947 |
| [Ie] rated operational current | 500 A (at 400 A (at 700 A (at <40 °C) at <= 440 V AC AC-1 for power circuit |
| [Ith] conventional free air thermal current | 700 A (at 40 °C) for power circuit |
All specifications
| Parameter | Value |
|---|---|
| Motor power | 147 kW at 220/230 V AC 50/60 Hz 250 kW at 380/400 V AC 280 kW at 415 V AC 295 kW at 440 V AC 335 kW at 500 V AC 355 kW at 660/690 V AC |
| Inrush power in | 1100 VA 50 Hz cos phi 0.9 (at 20 °C) 1100 VA 60 Hz cos phi 0.9 (at 20 °C) |
| Power dissipation per pole | 45 W AC-3 88 W AC-1 |
| Hold-in power consumption in | 18 VA 50 Hz cos phi 0.9 (at 20 °C) 18 VA 60 Hz cos phi 0.9 (at 20 °C) |
| Poles description | 3P |
| Pole contact composition | 3 NO |
| Utilisation category | AC-3 AC-3e AC-1 |
| IP degree of protection | IP00 conforming to IEC 60529 |
| Mounting support | Plate |
| Connections - terminals | Power circuit: cable with lug 2 1...4 mm² - external diameter: 240 mm - cable stiffness: flexible without cable end Power circuit: bars 2 1...4 mm² - cable stiffness: flexible without cable end - busbar cross section: 40 x 5 mm Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - external diameter: 240 mm - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid without cable end - busbar cross section: 40 x 5 mm |
| Pollution degree | 3 |
| Operating altitude | 3000 m without derating |
| Depth | 232 mm |
| Width | 233 mm |
| Height | 400 mm |
| Product weight | 11.35 kg |
| Electrical durability | 250000 cycles AC-1 600000 cycles AC-3 |
| Mechanical durability | 4000000 cycles |
| Standards | EN/IEC 60947-1 EN/IEC 60947-4-1 GB/T 14048.1 GB/T 14048.4 |
| Range | Easy TeSys |
| Operating time | 100...170 ms on opening 40...75 ms on closing |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Heat dissipation | 18 W for control circuit 18 W |
| Average impedance | 0.18 mOhm - Ith 700 A 50 Hz for power circuit |
| Device short name | LC1E |
| Tightening torque | Control circuit: 1.2 N.m Power circuit: 35 N.m |
| Overvoltage category | III |
| Contactor application | Motor control Resistive load |
| Mechanical robustness | Shocks contactor closed (15 Gn for 11 ms) Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor open (9 Gn for 11 ms) |
| Associated fuse rating | 800 A gG at <= 690 V coordination type 1 for power circuit |
| Maximum operating rate | 2400 cyc/h 55 °C |
| Irms rated making capacity | 5000 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
| Auxiliary contact composition | Without |
| Permissible ambient air temperature around the device | -20...70 °C at Uc -60...80 °C storage -5...55 °C operation |
MPN
LC1E500N7