Specifications

LC1F150P7 key specifications
ParameterValue
Range of productTeSys F
Control circuit typeAC at 40...400 Hz
Product or component typeContactor
Coil voltage230 V AC 40...400 Hz
Voltage1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Control circuit voltage limitsOperational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)
[Ue] rated operational voltage<= 460 V DC
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current1200 A 40 °C - 10 s 700 A 40 °C - 30 s 600 A 40 °C - 1 min 450 A 40 °C - 3 min 350 A 40 °C - 10 min
Breaking capacity1200 A conforming to IEC 60947-4-1
[Ie] rated operational current250 A (at 150 A (at <55 °C) at <= 440 V AC-3
[Ith] conventional free air thermal current250 A (at 40 °C)

All specifications

LC1F150P7 additional specifications
ParameterValue
Motor power75 kW at 380...400 V AC 50/60 Hz (AC-3) 80 kW at 415 V AC 50/60 Hz (AC-3) 80 kW at 440 V AC 50/60 Hz (AC-3) 90 kW at 500 V AC 50/60 Hz (AC-3) 100 kW at 660...690 V AC 50/60 Hz (AC-3) 40 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 400 V AC 50/60 Hz (AC-4)
Inrush power in770 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Power dissipation per pole22 W AC-1 8 W AC-3
Power pole contact composition3 NO
Hold-in power consumption in8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Poles description3P
Utilisation categoryAC-1 AC-4 AC-3
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Mounting supportPlate
Connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 120 mm² Power circuit: connector 1 cable(s) 120 mm² Power circuit: bolted connection
Operating altitude3000 m without derating
Depth171 mm
Width163.5 mm
Height170 mm
Product weight3.43 kg
Mechanical durability10 Mcycles
StandardsIEC 60947-4-1 IEC 60947-1 JIS C8201-4-1 EN 60947-1 EN 60947-4-1
RangeTeSys
Operating time35 ms closing (at Uc) 130 ms opening (at Uc)
Heat dissipation5.9...7.2 W
Average impedance0.35 mOhm - Ith 250 A 50 Hz
Device short nameLC1F
Tightening torqueControl circuit: 1.2 N.m Power circuit: 18 N.m
Compatibility codeLC1F
Overvoltage categoryIII
Protective treatmentTH
Contactor applicationResistive load Motor control
Associated fuse rating160 A aM at 250 A gG at <= 440 V
Maximum operating rate2400 cyc/h 55 °C
Ambient air temperature for storage-60...80 °C
Ambient air temperature for operation-40...60 °C
Permissible ambient air temperature around the device60...70 °C at Uc
MPN
LC1F150P7