Skip to main content
Schneider Electric LC1F1854

Schneider LC1F1854 TeSys F contactor, 4-pole, 275 A AC-1

MPNLC1F1854
Obsolete

Schneider Electric TeSys F LC1F1854 contactor, 4-pole, 275 A AC-1 resistive load, 24 V coil, 1850 A making capacity, IP2X, plate mount, 208 x 180 mm footprint.

$711.20Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LC1F1854 key specifications
ParameterValue
Product or component typeContactor
Coil voltage24...575 V AC 40...400 Hz with LX9 coil 24...460 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil
Voltage1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Control circuit voltage limitsOperational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.15...0.2 Uc DC with LX4 coil Operational: 85...275 V AC 50/60 Hz with LXE coil Drop-out: 0...60 V AC 50/60 Hz with LXE coil Operational: 85...418 V DC with LXE coil Drop-out: 0...45 V DC with LXE coil
[Ue] rated operational voltage<= 460 V DC
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current1500 A 104 °F (40 °C) - 10 s 920 A 104 °F (40 °C) - 30 s 740 A 104 °F (40 °C) - 1 min 500 A 104 °F (40 °C) - 3 min 400 A 104 °F (40 °C) - 10 min
Breaking capacity1480 A conforming to IEC 60947-4-1
[Ie] rated operational current275 A 104 °F (40 °C)) <= 440 V AC-1
[Ith] conventional free air thermal current275 A (at 104 °F (40 °C))
Inrush power in950...1180 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil 737...902 VA (at 68 °F (20 °C))with LX4 coil 280...310 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 270...320 VA (at 68 °F (20 °C))with LXE coil
Power dissipation per pole25 W AC-1

All specifications

LC1F1854 additional specifications
ParameterValue
Power pole contact composition4 NO
Hold-in power consumption in8.9...10.9 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil 4.13...5.07 VA (at 68 °F (20 °C))with LX4 coil 4.5...7.0 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 2.5...4.0 VA (at 68 °F (20 °C))with LXE coil
Poles description4P
Utilisation categoryAC-1
IP degree of protectionIP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106
Mounting supportPlate
Connections - terminalsPower circuit bar 2 25 x 3 mm Power circuit lugs-ring terminals 1 0.2 in² (150 mm²) Power circuit connector 1 0.2 in² (150 mm²) Power circuit bolted connection Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) Control circuit screw clamp terminals 1.0 0.0003...0.004 in² (0.2...2.5 mm²)flexible without cable end Control circuit screw clamp terminals 1.0 0.0004...0.004 in² (0.25...2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1.0 0.0003...0.004 in² (0.2...2.5 mm²)solid without cable end
Operating altitude9842.52 ft (3000 m) without derating
Depth7.1 in (181 mm)
Width8.2 in (208.5 mm)
Height6.9 in (174 mm)
Mechanical durability10 Mcycles
StandardsEN 60947-4-1 IEC 60947-1 EN 60947-1 JIS C8201-4-1 IEC 60947-4-1
RangeTeSys
CategoryUS10I1222336
Operating time35 ms closing with LX9 coil 130 ms opening with LX9 coil 30...40 ms closing with LX4 coil 30...50 ms opening with LX4 coil 40...80 ms closing with LXE coil 6...54 ms opening with LXE coil
Heat dissipation8...9.8 W 2.2...2.5 W
Average impedance0.33 mOhm - Ith 275 A 50 Hz
Device short nameLC1F
Tightening torquePower circuit 159.3 lbf.in (18 N.m) Control circuit 10.6 lbf.in (1.2 N.m) Control circuit 5.3 lbf.in (0.6 N.m)
Compatibility codeLC1F
Overvoltage categoryIII
Protective treatmentTH
Contactor applicationResistive load
Mechanical robustnessVibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed5 Gn, 5...300 Hz Shocks contactor open7 Gn for 1/2 sine wave (11 ms) Shocks contactor closed15 Gn for 1/2 sine wave (11 ms)
Associated fuse rating315 A gG at <= 440 V
Maximum operating rate2400 cyc/h 131 °F (55 °C)
Irms rated making capacity1850 A conforming to IEC 60947-4-1
Ambient air temperature for storage-76...176 °F (-60...80 °C)
Ambient air temperature for operation23...131 °F (-5...55 °C)
Permissible ambient air temperature around the device-40...158 °F (-40...70 °C)

Product details

Overview

The LC1F1854 is a TeSys F 4-pole contactor rated 275 A in AC-1 utilization category for resistive loads, with a 1850 A making capacity and 1.48 kA breaking capacity per IEC 60947-4-1. It carries a 24 V coil drawing 8.9 W holding power, mounts to a plate, and is sealed to IP2X with TH protective treatment for damp environments.

Compared to the 3-pole LC1D150P7 rated 250 A, the LC1F1854 adds a fourth pole and 25 A more continuous current — 275 A vs 250 A — making it the choice when a neutral or auxiliary pole must switch the same resistive load without a separate contactor.

MPN
LC1F1854