Specifications
| Parameter | Value |
|---|---|
| Range of product | TeSys F |
| Control circuit type | AC 50/60 Hz electronic DC electronic |
| Product or component type | Contactor |
| Input voltage limits | 0...5 V off-state PLC 11...30 V on-state PLC |
| Coil voltage | 100...250 V AC 50/60 Hz 100...250 V DC |
| Voltage | 1000 V IEC 60947-4-1 1000 V UL 60947-4-1 |
| Control circuit voltage limits | Operational 85...275 V AC/DC 131 °F (55 °C)) Drop-out 0...65 V AC 50/60 Hz 131 °F (55 °C)) Drop-out 0...51 V DC 131 °F (55 °C)) |
| [Ue] rated operational voltage | <= 1000 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Icw] rated short-time withstand current | 12000 A 104 °F (40 °C) - 10 s 9000 A 104 °F (40 °C) - 30 s 7000 A 104 °F (40 °C) - 1 min 6000 A 104 °F (40 °C) - 3 min 4000 A 104 °F (40 °C) - 10 min |
| Breaking capacity | 3900 A conforming to IEC 60947-4-1 |
| [Ie] rated operational current | 2600 A (at <140 °F (60 °C)) AC-1 |
All specifications
| Parameter | Value |
|---|---|
| [Ith] conventional free air thermal current | 2600 A (at 104 °F (40 °C)) |
| Inrush power in | 1100...2300 VA, 50/60 Hz 0.5 68 °F (20 °C)) |
| Power dissipation per pole | 250 W AC-1 |
| Hold-in power consumption in | 21.1...24.5 VA, 50/60 Hz 0.5 68 °F (20 °C)) |
| Power pole contact composition | 3 NO |
| Poles description | 3P |
| Utilisation category | AC-1 |
| Mounting support | Plate |
| Connections - terminals | Power circuit bar 3 100 x 10 mm Control circuit screw clamp terminals 1 0.0003...0.004 in² (0.2...2.5 mm²)solid Control circuit screw clamp terminals 1 0.0003...0.004 in² (0.2...2.5 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.0004...0.004 in² (0.25...2.5 mm²)flexible with cable end |
| Operating altitude | 9842.52 ft (3000 m) without derating |
| Depth | 9.9 in (251 mm) |
| Width | 20.4 in (519 mm) |
| Height | 15.04 in (382 mm) |
| Mechanical durability | 0.5 Mcycles |
| Standards | EN/IEC 60947-4-1 EN/IEC 60947-1 JIS C8201-4-1 UL 60947-4-1 |
| Range | TeSys |
| Operating time | 54...88 ms closing 20...28 ms opening |
| Heat dissipation | 16...20 W |
| Average impedance | 0.1 mOhm - Ith 2600 A 50 Hz |
| Device short name | LC1F |
| Tightening torque | Power circuit 462.008...564.7 lbf.in (52.2...63.8 N.m) Control circuit 4.4...5.3 lbf.in (0.5...0.6 N.m) |
| Compatibility code | LC1F |
| Input compatibility | PLC 24 V DC IEC 61131-2 Type 2 |
| Overvoltage category | III |
| Contactor application | Resistive load |
| Associated fuse rating | 2500 A gG at <= 440 V |
| Maximum operating rate | 600 cyc/h 131 °F (55 °C) |
| Irms rated making capacity | 3900 A conforming to IEC 60947-4-1 |
| Ambient air temperature for storage | -76...176 °F (-60...80 °C) |
| Ambient air temperature for operation | 23...104 °F (-5...40 °C) |
| Permissible ambient air temperature around the device | -40...140 °F (-40...60 °C) |
MPN