| Parameter | Value |
|---|---|
| Range of product | TeSys F |
| Motor starter type | Direct on-line contactor |
| Control circuit type | DC standard AC 40...400 Hz |
| Product or component type | Contactor |
| Contactor coil voltage | 400 V DC standard 400 V AC standard 380 V AC standard 415 V AC standard |
| Coil voltage | 400 V DC 380...415 V AC 40...400 Hz |
| Voltage | 1000 V IEC 60947-4-1 1500 V VDE 0110 group C |
| Control circuit voltage limits | Operational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C)) |
| [Ue] rated operational voltage | <= 460 V DC |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Icw] rated short-time withstand current | 5500 A 104 °F (40 °C) - 10 s 4600 A 104 °F (40 °C) - 30 s 3600 A 104 °F (40 °C) - 1 min 2600 A 104 °F (40 °C) - 3 min 1700 A 104 °F (40 °C) - 10 min |
| Breaking capacity | 6400 A conforming to IEC 60947-4-1 |
All specifications
| Parameter | Value |
|---|---|
| [Ie] rated operational current | 1000 A (at 800 A (at <131 °F (55 °C)) at <= 440 V AC AC-3 |
| [Ith] conventional free air thermal current | 1000 A (at 104 °F (40 °C)) |
| Motor power | 450 kW at 1000 V AC 50/60 Hz (AC-3) 450 kW at 500 V AC 50/60 Hz (AC-3) 475 kW at 660...690 V AC 50/60 Hz (AC-3) 110 kW at 400 V AC 50/60 Hz (AC-4) 450 kW at 380...400 V AC 50/60 Hz (AC-3) 450 kW at 415 V AC 50/60 Hz (AC-3) 450 kW at 440 V AC 50/60 Hz (AC-3) 250 kW at 220...230 V AC 50/60 Hz (AC-3) |
| Inrush power in | 1900 W 68 °F (20 °C)) |
| Motor power range | 250...500 kW 200...240 V 3 phase 250...500 kW 380...440 V 3 phase 110...220 kW 200...240 V 3 phase 250...500 kW 480...500 V 3 phase |
| Power dissipation per pole | 120 W AC-1 77 W AC-3 |
| Hold-in power consumption in | 12 W 68 °F (20 °C) |
| Power pole contact composition | 3 NO |
| Poles description | 3P |
| Utilisation category | AC-3 AC-1 AC-4 |
| IP degree of protection | IP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106 |
| Mounting support | Plate |
| Connections - terminals | Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable end Power circuit bar 2 60 x 5 mm Power circuit bolted connection |
| Operating altitude | 9842.52 ft (3000 m) without derating |
| Depth | 10.04 in (255 mm) |
| Width | 12.2 in (309 mm) |
| Height | 12.0 in (304 mm) |
| Mechanical durability | 5 Mcycles |
| Standards | JIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 IEC 60947-1 EN 60947-1 |
| Range | TeSys |
| Category | US10I1222336 |
| Operating time | 40...50 ms opening 60...80 ms closing |
| Heat dissipation | 12 W |
| Average impedance | 0.12 mOhm - Ith 1000 A 50 Hz |
| Device short name | LC1F |
| Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 513.3 lbf.in (58 N.m) |
| Compatibility code | LC1F |
| Overvoltage category | III |
| Protective treatment | TH |
| Contactor application | Resistive load Motor control |
| Associated fuse rating | 1000 A gG at 800 A aM at <= 440 V |
| Maximum operating rate | 600 cyc/h 131 °F (55 °C) |
| Ambient air temperature for storage | -76...176 °F (-60...80 °C) |
| Ambient air temperature for operation | 23...131 °F (-5...55 °C) |
| Permissible ambient air temperature around the device | 23...131 °F (-5...55 °C) |
MPN