LC1F800QW key specifications
ParameterValue
Range of productTeSys F
Motor starter typeDirect on-line contactor
Control circuit typeDC standard AC 40...400 Hz
Product or component typeContactor
Contactor coil voltage400 V DC standard 400 V AC standard 380 V AC standard 415 V AC standard
Coil voltage400 V DC 380...415 V AC 40...400 Hz
Voltage1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))
[Ue] rated operational voltage<= 460 V DC
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current5500 A 104 °F (40 °C) - 10 s 4600 A 104 °F (40 °C) - 30 s 3600 A 104 °F (40 °C) - 1 min 2600 A 104 °F (40 °C) - 3 min 1700 A 104 °F (40 °C) - 10 min
Breaking capacity6400 A conforming to IEC 60947-4-1

All specifications

LC1F800QW additional specifications
ParameterValue
[Ie] rated operational current1000 A (at 800 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Ith] conventional free air thermal current1000 A (at 104 °F (40 °C))
Motor power450 kW at 1000 V AC 50/60 Hz (AC-3) 450 kW at 500 V AC 50/60 Hz (AC-3) 475 kW at 660...690 V AC 50/60 Hz (AC-3) 110 kW at 400 V AC 50/60 Hz (AC-4) 450 kW at 380...400 V AC 50/60 Hz (AC-3) 450 kW at 415 V AC 50/60 Hz (AC-3) 450 kW at 440 V AC 50/60 Hz (AC-3) 250 kW at 220...230 V AC 50/60 Hz (AC-3)
Inrush power in1900 W 68 °F (20 °C))
Motor power range250...500 kW 200...240 V 3 phase 250...500 kW 380...440 V 3 phase 110...220 kW 200...240 V 3 phase 250...500 kW 480...500 V 3 phase
Power dissipation per pole120 W AC-1 77 W AC-3
Hold-in power consumption in12 W 68 °F (20 °C)
Power pole contact composition3 NO
Poles description3P
Utilisation categoryAC-3 AC-1 AC-4
IP degree of protectionIP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106
Mounting supportPlate
Connections - terminalsControl circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable end Power circuit bar 2 60 x 5 mm Power circuit bolted connection
Operating altitude9842.52 ft (3000 m) without derating
Depth10.04 in (255 mm)
Width12.2 in (309 mm)
Height12.0 in (304 mm)
Mechanical durability5 Mcycles
StandardsJIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 IEC 60947-1 EN 60947-1
RangeTeSys
CategoryUS10I1222336
Operating time40...50 ms opening 60...80 ms closing
Heat dissipation12 W
Average impedance0.12 mOhm - Ith 1000 A 50 Hz
Device short nameLC1F
Tightening torqueControl circuit 10.6 lbf.in (1.2 N.m) Power circuit 513.3 lbf.in (58 N.m)
Compatibility codeLC1F
Overvoltage categoryIII
Protective treatmentTH
Contactor applicationResistive load Motor control
Associated fuse rating1000 A gG at 800 A aM at <= 440 V
Maximum operating rate600 cyc/h 131 °F (55 °C)
Ambient air temperature for storage-76...176 °F (-60...80 °C)
Ambient air temperature for operation23...131 °F (-5...55 °C)
Permissible ambient air temperature around the device23...131 °F (-5...55 °C)