Schneider Electric TeSys Giga LC1G1854LSEN power contactor, 4 NO poles, 200-500 V AC/DC control circuit, AC-3/AC-1/DC utilisation, dark grey, 7.6 in depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC1G1854LSEN — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationPower switching
LC1G1854LSEN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-3 AC-3e AC-1 AC-5a AC-5b AC-6a AC-6b DC-1 DC-3 DC-5
LC1G1854LSEN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1G1854LSEN — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106
Mechanical robustnessVibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed
Protective treatment / pollution degreeTH
LC1G1854LSEN — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ
LC1G1854LSEN — Mechanical
ParameterValue
Width5.6 in (143 mm)
Height7.6 in (193 mm)
Depth7.6 in (193 mm)

Product details

The LC1G1854LSEN is a 4-pole (4 NO) power contactor from the TeSys Giga range, built for heavy power switching in motor and resistive load applications. Rated insulation voltage is 1000 V, and it handles utilisation categories AC-3, AC-3e, AC-1, AC-5a, AC-5b, AC-6a, AC-6b, DC-1, DC-3, and DC-5 — meaning it switches motor loads, resistive heaters, and DC circuits across a wide industrial range. Safety reliability is documented with B10d values of 400,000 cycles at nominal load and 3,000,000 cycles at mechanical load per EN/ISO 13849-1.

Power dissipation per pole is 20 W in AC-1 at Ith 305 A and 6 W in AC-3 at Ith 185 A — this drives the thermal budget inside the enclosure; the 0.00017 Ohm average impedance confirms low resistive losses at rated current. Associated fuse ratings are listed for multiple standards: 200 A aM, 160 A aM, 315 A gG, and 300 A UL Type J at ≤600 V — giving the panel builder a direct guide for short-circuit protection coordination without derating guesswork.

Mounting and integration details

Mounting is plate-based (not direct DIN rail), with a connection pitch of 35 mm. The power circuit accepts bar or busbar cross-section up to 25 x 6 mm, or ring terminals up to 185 mm². Tightening torque for power connections is 159.3 lbf·in (18 N·m). The depth is 7.6 in (193 mm), width 5.6 in (143 mm), and height 7.6 in (193 mm) — dimensions that matter when planning gland plate clearance and fill factor in a multi-contactor lineup. IP degree of protection is IP2X on the front face with shrouds per IEC 60529 and VDE 0106, meaning finger-safe but not sealed against moisture — suitable for indoor panel installation with proper enclosure.

Frequently asked questions

How do I get pricing and availability for LC1G1854LSEN?

Submit an RFQ for the LC1G1854LSEN. No stock-holding claim is made; each order is quoted individually.

What compliance documentation does Schneider Electric provide for LC1G1854LSEN?

Protective treatment is TH (tropicalised).