Schneider Electric LC1G185LSEN — Contactors

Schneider Electric LC1G185LSEN TeSys Giga Contactor, 185 A,

MPNLC1G185LSEN
Active

Schneider Electric TeSys Giga series, LC1G185LSEN, 3-pole contactor, 185 A rated, 90 kW at 400 V AC-3e, 200-500 V AC/DC coil, dark grey.

$990.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC1G185LSEN — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationPower switching Motor control
LC1G185LSEN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5
LC1G185LSEN — Contacts & Poles
ParameterValue
Pole configuration3P
LC1G185LSEN — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106
Mechanical robustnessVibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed
Protective treatment / pollution degreeTH
LC1G185LSEN — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ
LC1G185LSEN — Mechanical
ParameterValue
Width4.3 in (108 mm)
Height7.6 in (193 mm)
Depth7.6 in (193 mm)

Product details

The Schneider Electric LC1G185LSEN is a 3-pole contactor from the TeSys Giga series, rated for 185 A in AC-1 duty and delivering 90 kW at 400 V AC in AC-3e motor-switching service. It handles motor loads from 55 kW at 230 V up to 110 kW at 690 V in AC-3e, and carries a North American horsepower rating of 125 hp at 460/480 V 60 Hz. This contactor covers a wide range of utilisation categories — AC-1 through AC-8b and DC-1 through DC-5 — making it suitable for resistive heating, motor starting (including reversing and plugging), capacitor switching, and DC loads up to its rated breaking capacity of 1610 A at 440 V. The 3 NO main poles and integrated 1 NO + 1 NC auxiliary contacts mean you can handle feedback and interlocking without an add-on block in many panel layouts.

The AC-3e rating at 400 V (90 kW) is the one that governs most motor-starting applications in European and Asian 400 V three-phase networks — it's the duty cycle that matters for squirrel-cage motors, not the higher AC-1 resistive current. For North American 60 Hz panels, the 125 hp at 460/480 V rating is the equivalent gate. The 8 Mcycles mechanical durability means this contactor will outlast the machine in most cyclic applications; the B10d of 400,000 cycles at nominal load (per EN/ISO 13849-1) is the safety-relevant figure for guarding circuits. Power dissipation per pole runs 20 W in AC-1 at 305 A and 6 W in AC-3 at 185 A — that's the heat you need to account for in a sealed enclosure. The 0.00017 Ω average impedance confirms low losses for a contactor this size. Maximum operating rate is 600 cycles/hour in AC-3/AC-3e, 300 in AC-1, and 150 in AC-4 — the AC-4 figure is the limiter for reversing or inching duty.

Compliance documentation covers EN/IEC 60947-4-1 and 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1/5-1. It also meets IEC 60335-1 Clause 30.2 and IEC 60335-2-40 Annex JJ for appliance applications, plus UL 60335-1 and UL 60335-2-40 Annex JJ.

Mounts on a plate (not direct DIN rail — the 35 mm connection pitch is the pole spacing, not the rail pitch). Power connections accept bar or busbar up to 25 x 6 mm, or ring terminals up to 185 mm². Tightening torque for power terminals is 18 N·m (159.3 lbf·in). The IP2X front face with shrouds meets IEC 60529 and VDE 0106 for finger-safe installation. Dimensions are 7.6 x 4.3 x 7.6 in (193 x 108 x 193 mm) — a compact footprint for a 185 A frame. The dark grey housing is standard for the TeSys Giga range. Associated fuse ratings are 200 A aM or 315 A gG at the line side; UL Type J fuses at 300 A for North American installations.

Frequently asked questions

What compliance documentation does this contactor carry?

It is certified to EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, and JIS C8201-5-1. It also meets IEC 60335-1 Clause 30.2 and IEC 60335-2-40 Annex JJ for appliance applications.

What is the closest alternative in the TeSys family?

Within the TeSys Giga range, the LC1G185LSEN is the 185 A frame with a 200–500 V AC/DC coil. A lower-coil-voltage variant (e.g., 24 V or 110 V) would be a different order code but the same power pole and mounting footprint. There is no pin-compatible drop-in from the older TeSys F or D ranges — the Giga series uses a different mounting plate and terminal layout.

What are the key specifications for a BOM check?

3-pole, 185 A AC-1, 90 kW at 400 V AC-3e, 125 hp at 460/480 V 60 Hz. Coil 200–500 V AC/DC. Dimensions 193 x 108 x 193 mm. Weight is not listed but the frame size suggests roughly 2–3 kg. Mechanical durability 8 Mcycles.

MPN
LC1G185LSEN