For motor loads or DC drives with significant inductance, you would need to check the DC-3 or DC-5 rating (not listed here) or add an external snubber. The ≤1500V voltage rating covers common 1000V and 1500V DC rail systems used in solar, UPS, and traction applications. The wideband coil (200-500V AC/DC) means the pick-up and drop-out thresholds are designed for that entire range — verify your control voltage is within that window, not just at the nominal panel voltage. A 24V control bus will not drive this coil.
Schneider Electric LC1G250DCLSEN TeSys Giga DC Contactor, 25
MPNLC1G250DCLSEN
Active
Schneider Electric TeSys Giga series, LC1G250DCLSEN, 3-pole DC contactor, DC-1 ≤1500V 250A, 200...500V wideband AC/DC coil, standard version.
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Product details
Frequently asked questions
What is the DC-1 current rating and what does it cover?
Rated 250A at DC-1 ≤1500V. DC-1 covers resistive and lightly inductive DC loads — heaters, DC bus precharge, battery banks. For inductive DC motor or drive loads, verify the DC-3/DC-5 rating separately.
What coil voltage does this contactor accept?
The coil accepts a wideband 200...500V supply, both AC and DC. No separate coil variant is needed for that range.
MPN
LC1G250DCLSEN