Skip to main content
Schneider Electric LC1G5004LSEN — Contactors

TeSys Giga LC1G5004LSEN Contactor, 4-Pole, 700A AC-1

MPNLC1G5004LSEN
Active

TeSys Giga LC1G5004LSEN 4-pole contactor, 700A AC-1 / 500A AC-3, 200-500V AC/DC coil, built-in peak limiting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC1G5004LSEN — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationPower switching
LC1G5004LSEN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)<= 460 V DC
Utilisation categoryAC-3 AC-3e AC-1 AC-5a AC-5b AC-6a AC-6b DC-1 DC-3 DC-5
LC1G5004LSEN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1G5004LSEN — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106
Mechanical robustnessVibrations 5...300 Hz 2 gn contactor open Vibrations 5...300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed
Protective treatment / pollution degreeTH
LC1G5004LSEN — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 UL 60335-1 UL 60335-2-40:Annex JJ
LC1G5004LSEN — Mechanical
ParameterValue
Width7.3 in (185 mm)
Height8.9 in (225 mm)
Depth8.9 in (226 mm)

Product details

Integrator's note: what this contactor brings to the panel

The TeSys Giga LC1G5004LSEN is a 4-pole power contactor rated 700 A in AC-1 (resistive) and 500 A in AC-3 (motor) duty, with a control voltage range of 200–500 V AC or DC. That dual-voltage coil, combined with built-in bidirectional peak limiting, removes the need for an external MOV or RC snubber — one less component to fail and one less wiring point to check during commissioning. Mechanical durability is 8 million cycles, and the contactor stays closed under vibration up to 4 gn. For a concurrently maintainable installation, that means fewer unplanned swaps over the facility's life. Operating times are 40–70 ms closing and 15–50 ms opening — fast enough for most transfer schemes, but verify coordination if your logic demands sub-cycle break-before-make.

Mounting and wiring — panel integration checklist

Mounts on a plate (plate mounting specified). Overall footprint: 8.9 in deep (226 mm), 8.9 in high (225 mm), 7.3 in wide (185 mm). Connection pitch is 45 mm — verify spacing if replacing an existing contactor in a tight layout. Power circuit terminals accept bar (2 x 32×10 mm cross-section) or ring lugs up to 185 mm². Tightening torque 35 N·m (309.8 lbf·in). Strip to 8–10 mm; spring-cage retention eliminates screw torque verification. IP2X front face achieved with supplied shrouds — fit them before energizing. Auxiliary contacts: 1 NO + 1 NC integrated. Safety reliability B10d = 400,000 cycles at nominal load per EN/ISO 13849-1.

Frequently asked questions

What is the listed color of LC1G5004LSEN?

Dark grey.

What is the depth of LC1G5004LSEN?

8.9 in (226 mm).

What compliance standards does this contactor meet?

It meets EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, JIS C8201-5-1, UL 60335-1, and UL 60335-2-40 Annex JJ.

MPN
LC1G5004LSEN