ParameterValue
Auxiliary contacts typeInstantaneous 1 NO
Product or component typeContactor
Minimum switching voltage17 V for signalling circuit
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at Drop-out: >= 0.20 Uc (at <122 °F (50 °C))
[Ue] rated operational voltagePower circuit Signalling circuit 10 MOhm for signalling circuit
Minimum switching current5 mA for signalling circuit
Inrush power in30 VA (at 68 °F (20 °C))
Power pole contact composition3 NO
Hold-in power consumption in4.5 VA (at 68 °F (20 °C))
Signalling circuit frequency<= 400 Hz
Poles description3P
Utilisation categoryAC-3 AC-3e

All specifications

LC1K16106M7 additional specifications
ParameterValue
IP degree of protectionIP2X VDE 0106
Mounting supportPlate Rail
Connections - terminalslugs-ring terminals 0.3 in (7 mm))
Operating altitude6561.68 ft (2000 m) without derating
Depth2.2 in (57 mm)
Width1.8 in (45 mm)
Height2.3 in (58 mm)
Electrical durability1.3 Mcycles 16 A AC-3 1.3 Mcycles 16 A AC-3e <= 440 V
Mechanical durability10 Mcycles
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ
RangeTeSys
CategoryUS10I1222326
Operating time10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing
Coil technologyWithout built-in suppressor module
Flame retardanceV1 conforming to UL 94
Heat dissipation1.3 W
Device short nameLC1K
Tightening torque7.08...11.5 lbf.in (0.8...1.3 N.m) lugs-ring terminals Philips No 2 7.08...11.5 lbf.in (0.8...1.3 N.m) lugs-ring terminals flat Ø 6 mm 7.08...11.5 lbf.in (0.8...1.3 N.m) lugs-ring terminals pozidriv No 2
Device applicationControl
Non overlap distance0.02 in (0.5 mm)
Protective treatmentTC IEC 60068 TC DIN 50016
Contactor applicationMotor control
Mechanical robustnessShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Maximum operating rate3600 cyc/h
Safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Ambient air temperature for storage-58...176 °F (-50...80 °C)
Ambient air temperature for operation-13...122 °F (-25...50 °C)

Product details

The Schneider TeSys LC1K16106M7 is a 3-pole contactor built for motor control in the AC-3 duty class. It's rated to switch 16 A under those motor loads, with an electrical endurance of 1.3 million cycles – enough for years of daily starting in a pump or fan panel. The coil draws 4.5 VA holding power and 30 VA inrush at 20 °C, and it's shipped without a built-in suppressor module, so you add the RC snubber or varistor to match the control voltage. Out here in the grease, 10 million mechanical cycles means you'll retire the machine before this contactor gives up. The contacts are rated for a minimum switching of 5 mA at 17 V, so it'll handle signalling circuits alongside the power poles. Panel footprint is compact at 45 mm wide by 58 mm tall – fits a standard DIN rail without eating up the whole enclosure.

Heat dissipation is 1.3 W steady-state, so no special ventilation needed in a typical steel enclosure. The 1 NO auxiliary contact is integrated and rated for the same AC-3 duty as the main poles. If you need more aux contacts, snap-on TeSys K auxiliary blocks exist – but verify compatibility with the LC1K frame.

This contactor meets EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and JIS C8201-4-1. It also complies with IEC 60335-1 Clause 30.2 and the Annex JJ requirements for appliance applications. The housing flame retardance is V1 per UL 94. You can expect the standard UL/CE/CCC marks on the nameplate.

Frequently asked questions

What is the depth of the LC1K16106M7?

Listed depth is 2.2 in (57 mm).

What is the range of this contactor?

It belongs to the Schneider TeSys range.

What compliance standards does the LC1K16106M7 meet?

It complies with EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, JIS C8201-4-1, and IEC 60335-1 Clause 30.2 and Annex JJ.

MPN