Skip to main content
Schneider Electric LC2F115M7

Schneider Electric LC2F115M7

MPNLC2F115M7
Obsolete

TeSys F reversing contactor - 3P(3 NO) AC-3 <= 440 V 115 A 220 V AC 40...400 Hz

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2F115M7 key specifications
ParameterValue
Interlocking typeMechanical
Control circuit typeAC at 40...400 Hz
Product or component typeReversing contactor
Coil voltage220 V AC 40...400 Hz
Voltage1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Control circuit voltage limitsOperational: 0.85...1.1 Uc at 50/60 Hz (at Drop-out: 0.2...0.55 Uc at 50/60 Hz (at <55 °C)
[Ue] rated operational voltage<= 460 V DC
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current1100 A 40 °C - 10 s 640 A 40 °C - 30 s 520 A 40 °C - 1 min 400 A 40 °C - 3 min 320 A 40 °C - 10 min
Breaking capacity920 A conforming to IEC 60947-4-1
[Ie] rated operational current115 A (at 200 A (at <40 °C) at <= 440 V AC AC-1
[Ith] conventional free air thermal current200 A (at 40 °C)

All specifications

LC2F115M7 additional specifications
ParameterValue
Motor power55 kW at 380...400 V AC 50/60 Hz 59 kW at 415 V AC 50/60 Hz 59 kW at 440 V AC 50/60 Hz 65 kW at 1000 V AC 50/60 Hz 75 kW at 500 V AC 50/60 Hz 30 kW at 220...240 V AC 50/60 Hz 80 kW at 660...690 V AC 50/60 Hz
Inrush power in550 VA 50 Hz cos phi 0.3 (at 20 °C) 660 VA 60 Hz cos phi 0.3 (at 20 °C)
Power dissipation per pole5 W AC-3
Power pole contact composition3 NO
Hold-in power consumption in45 VA 50 Hz cos phi 0.3 (at 20 °C) 55 VA 60 Hz cos phi 0.3 (at 20 °C)
Poles description3P
Utilisation categoryAC-3 AC-1
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Mounting supportPlate
Connections - terminalsPower circuit: lugs-ring terminals 1 cable(s) 95 mm² Power circuit: connector 1 cable(s) 95 mm² Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm
Operating altitude3000 m without derating
Depth171 mm
Width345 mm
Height162 mm
Mechanical durability10 Mcycles
StandardsEN 60947-1 JIS C8201-4-1 EN 60947-4-1 IEC 60947-4-1 IEC 60947-1
RangeTeSys
Operating time23...35 ms closing 5...15 ms opening
Heat dissipation12...16 W
Average impedance0.37 mOhm - Ith 200 A 50 Hz
Device short nameLC2F
Tightening torquePower circuit: 10 N.m Control circuit: 1.2 N.m
Device presentationPreassembled with reversing power busbar
Overvoltage categoryIII
Protective treatmentTH
Contactor applicationResistive load Motor control
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 6 Gn, 5...300 Hz Shocks contactor open: 9 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms
Associated fuse rating125 A aM at 200 A gG at <= 440 V
Maximum operating rate2400 cyc/h 55 °C
Irms rated making capacity1150 A AC conforming to IEC 60947-4-1
Ambient air temperature for storage-60...80 °C
Ambient air temperature for operation-5...55 °C
Permissible ambient air temperature around the device-40...70 °C
MPN
LC2F115M7