Specifications

LC2F265M7 key specifications
ParameterValue
Interlocking typeMechanical
Control circuit typeAC 40...400 Hz
Product or component typeReversing contactor
Coil voltage220 V AC 40...400 Hz
Voltage1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Control circuit voltage limitsOperational: 0.85...1.1 Uc at 40...400 Hz (at Drop-out: 0.15...0.2 Uc at 40...400 Hz (at <131 °F (55 °C))
[Ue] rated operational voltage<= 460 V DC
[Uimp] rated impulse withstand voltage8 kV
[Icw] rated short-time withstand current2200 A 104 °F (40 °C) - 10 s 1230 A 104 °F (40 °C) - 30 s 950 A 104 °F (40 °C) - 1 min 620 A 104 °F (40 °C) - 3 min 480 A 104 °F (40 °C) - 10 min
Breaking capacity2120 A conforming to IEC 60947-4-1
[Ie] rated operational current265 A (at 350 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
[Ith] conventional free air thermal current350 A (at 104 °F (40 °C))

All specifications

LC2F265M7 additional specifications
ParameterValue
Motor power132 kW 380...400 V AC 50/60 Hz 140 kW 415 V AC 50/60 Hz 140 kW 440 V AC 50/60 Hz 147 kW 1000 V AC 50/60 Hz 160 kW 500 V AC 50/60 Hz 75 kW 220...240 V AC 50/60 Hz 160 kW 660...690 V AC 50/60 Hz
Inrush power in650 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))
Power dissipation per pole21 W AC-3
Power pole contact composition3 NO
Hold-in power consumption in10 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))
Poles description3P
Utilisation categoryAC-3 AC-1
IP degree of protectionIP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106
Mounting supportPlate
Connections - terminalsControl circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002...0.006 in² (1...4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002...0.006 in² (1...4 mm²)solid without cable end Power circuit bar 2 32 x 4 mm Power circuit connector 1 0.4 in² (240 mm²) Power circuit lugs-ring terminals 1 0.4 in² (240 mm²)
Operating altitude9842.52 ft (3000 m) without derating
Depth8.4 in (213 mm)
Width16.7 in (425 mm)
Height8.0 in (203 mm)
Mechanical durability10 Mcycles
StandardsIEC 60947-1 EN 60947-4-1 JIS C8201-4-1 IEC 60947-4-1 EN 60947-1
RangeTeSys
Category22337-CTR,F-LINE,AC,OPEN,REV
Operating time40...65 ms closing 100...170 ms opening
Heat dissipation8 W
Average impedance0.3 mOhm - Ith 350 A 50 Hz
Device short nameLC2F
Tightening torqueControl circuit 10.6 lbf.in (1.2 N.m) Power circuit 309.8 lbf.in (35 N.m)
Device presentationPreassembled with reversing power busbar
Overvoltage categoryIII
Protective treatmentTH
Contactor applicationMotor control Resistive load
Mechanical robustnessVibrations contactor open2 Gn, 5...300 Hz Shocks contactor closed15 Gn for 11 ms Vibrations contactor closed5 Gn, 5...300 Hz Shocks contactor open6 Gn for 11 ms
Associated fuse rating315 A aM at 400 A gG at <= 440 V
Maximum operating rate2400 cyc/h 131 °F (55 °C)
Irms rated making capacity2650 A AC conforming to IEC 60947-4-1
Ambient air temperature for storage-76...176 °F (-60...80 °C)
Ambient air temperature for operation23...131 °F (-5...55 °C)
Permissible ambient air temperature around the device-40...158 °F (-40...70 °C)
MPN