Skip to main content
Schneider Electric LC2K06013K7 — Contactors

TeSys K LC2K06013K7 reversing contactor, 3P, 6 A AC-3, 100 V

MPNLC2K06013K7
Obsolete

Schneider Electric TeSys K reversing contactor, LC2K06013K7, 3P, AC-3 ≤440 V 6 A, 1 NC, 100 V AC coil, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K06013K7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K06013K7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4
LC2K06013K7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K06013K7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K06013K7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

Its rated operational voltage on the power circuit is 690 V AC 50/60 Hz, and it carries an AC-3 rating of 6 A at ≤440 V. The coil is 100 V AC. IP20 finger protection (per VDE 0106) means it's safe for open-panel mounting where accidental contact is a concern.

Integration notes

The IP20 rating and V1 flame retardance (UL 94) suit it for enclosed control panels. The protective treatment conforms to IEC 60068 and DIN 50016 for corrosion resistance.

Frequently asked questions

What is the closest alternative to LC2K06013K7?

No official successor order code is listed. The closest form-fit-function equivalent would be a current TeSys K reversing contactor with 3 poles, a 100 V AC coil, and an AC-3 rating of 6 A at ≤440 V — a parametric search within the TeSys K range is the recommended approach.

What are the key ratings of LC2K06013K7?

It is a 3-pole reversing contactor rated AC-3 ≤440 V 6 A, with a 100 V AC coil. Power circuit rated operational voltage is 690 V AC 50/60 Hz. IP20 protection, V1 flame retardance, and operating temperature range -25 to 50 °C.

MPN
LC2K06013K7