Skip to main content
Schneider Electric LC2K06015V7 — Contactors

Schneider TeSys K LC2K06015V7 reversing contactor, 3P, 6 A A

MPNLC2K06015V7
Obsolete

Schneider Electric TeSys K reversing contactor, LC2K06015V7, 3P, AC-3 ≤440 V 6 A, 1 NC auxiliary, 400 V AC coil, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC2K06015V7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K06015V7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3 AC-3e
LC2K06015V7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K06015V7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K06015V7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

Mechanical and environmental specifications

Mechanical robustness is documented per IEC 60068-2-27 and IEC 60068-2-6: the contactor withstands 15 Gn shocks on Y and Z axes when closed, and 4 Gn vibrations from 5 to 300 Hz in the closed state. Protective treatment conforms to IEC 60068 and DIN 50016 for resistance to corrosive atmospheres.

Frequently asked questions

What is LC2K06015V7's listed depth?

The depth is 57 mm.

What is LC2K06015V7's listed range?

It belongs to the TeSys K range of contactors from Schneider Electric.

What compliance documentation does this part carry?

The contactor carries IP20 finger protection per VDE 0106, flame retardance V1 per UL 94 (also compliant with NF F 16-101 and NF F 16-102), and protective treatment conforming to IEC 60068 and DIN 50016. The manufacturer provides declarations of conformity for applicable directives; request these from your distributor.

MPN
LC2K06015V7