Skip to main content
Schneider Electric LC2K06015U7 — Contactors

Schneider TeSys K LC2K06015U7 Reversing Contactor, 6 A AC-3,

MPNLC2K06015U7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 6 A, 1 NC auxiliary, 230-240 VAC coil, IP20, depth 57 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K06015U7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K06015U7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4
LC2K06015U7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K06015U7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K06015U7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The 230-240 VAC coil is standard for European control voltages. IP20 means finger-safe terminals but no washdown tolerance; it lives inside a panel.

AC-4 rating (inching/plugging) is also listed, so it handles the higher stress of reversing duty where the motor is switched while still spinning. The 1 NC auxiliary contact is built in, giving you a feedback signal for the PLC or a mechanical interlock confirmation. Operating altitude of 2000 m without derating covers most installations; above that, air density drops and the contactor's thermal dissipation and dielectric strength need a reduction factor.

The contactor is rated for 10 Gn shock on the Y and Z axes when closed, and 4 Gn vibration at 5-300 Hz, so it survives moderate machine vibration without dropping out. Flame retardance meets UL 94 V1 and NF F 16-101, so it passes rail and building-material fire tests.

Frequently asked questions

What replaces LC2K06015U7?

No official successor order code is listed in the lifecycle record. A form-fit-function substitute from the current TeSys range would require a parametric check on mounting footprint, coil voltage (230-240 VAC), pole configuration (3P), and auxiliary contact count (1 NC). Contact your sourcing desk for a cross-reference against the active TeSys Deca or TeSys GV series.

What are the key ratings for LC2K06015U7?

It is a 3-pole reversing contactor rated 6 A in AC-3 duty at <=440 V, with a 230-240 VAC coil. It includes 1 NC auxiliary contact and is preassembled with the reversing power busbar. IP20 finger-safe protection, operating temperature -25 to 50 °C, altitude 2000 m without derating.

MPN
LC2K06015U7