Schneider Electric LC2K0601G72 — Contactors

Schneider Electric LC2K0601G72 TeSys K Reversing Contactor,

MPNLC2K0601G72
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 6 A at 440 V, 1 NC auxiliary, 120 V AC coil, IP20, preassembled with reversing power busbar.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K0601G72 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K0601G72 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit 690 V AC 50/60 Hz Signalling circuit 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4
LC2K0601G72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K0601G72 — Environmental
ParameterValue
IP degree of protectionIP20 VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Protective treatment / pollution degreeTC IEC 60068 TC DIN 50016
Flame retardanceV1 UL 94 Requirement 2 NF F 16-101 Requirement 2 NF F 16-102
LC2K0601G72 — Mechanical
ParameterValue
Width3.5 in (90 mm)
Height2.3 in (58 mm)
Depth2.2 in (57 mm)

Product details

The Schneider Electric LC2K0601G72 is a TeSys K reversing contactor, 3-pole, rated for AC-3 and AC-4 utilisation categories at 6 A up to 440 V, with a 120 V AC coil and one NC auxiliary contact. It's rated for operation up to 2000 m altitude without derating, which covers most standard industrial installations.

The AC-3 rating of 6 A at 440 V governs motor switching — that's the current the contactor can make and break for a squirrel-cage induction motor during starting and running. The AC-4 rating covers plugging and inching duty, which is harder on the contacts. If your application requires reversing under load (AC-4), this contactor is rated for it, but the electrical life will be shorter than AC-3-only duty. The 120 V AC coil is a fixed-voltage design — no dual-voltage or wide-range coil. Verify your control transformer taps before committing the BOM line. The 1 NC auxiliary is built in; if you need more auxiliary contacts, they must be added via the TeSys K add-on block (separate order). Mechanical robustness is documented: the contactor withstands 10 Gn shocks on X-axis and 15 Gn on Y and Z axes for 11 ms when closed, and 4 Gn vibration at 5-300 Hz when closed. That's sufficient for most industrial machinery but not for extreme mobile or marine environments without additional damping.

Frequently asked questions

What is the closest alternative to LC2K0601G72 in the TeSys family?

There is no official successor order code listed. A parametric replacement would need to match the 3-pole reversing contactor form factor, 6 A AC-3 rating at 440 V, 120 V AC coil, and 1 NC auxiliary. The TeSys K series includes other reversing contactors with different coil voltages or current ratings, but pin-compatibility and mounting footprint must be verified against the original panel layout.

What is the depth of LC2K0601G72?

The depth is 2.2 inches (57 mm).

MPN