Schneider Electric LC2K0601K72 — Contactors

TeSys K LC2K0601K72 reversing contactor, 3P, 6 A AC-3, 100 V

MPNLC2K0601K72
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 6 A, 1 NC, 100 V AC coil, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K0601K72 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K0601K72 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3
LC2K0601K72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K0601K72 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K0601K72 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

It switches a 3-phase motor up to 6 A at ≤440 V AC (AC-3), with a 100 V AC coil. The 1 NC auxiliary contact provides a feedback path for the reversing interlock or status monitoring.

Rated operational voltage on the power circuit is 690 V AC 50/60 Hz, so it can handle 400 V and 480 V line supplies without derating up to 2000 m altitude. The AC-3 rating (6 A at ≤440 V) governs motor switching — that is the current it can make and break across a standard induction motor load. AC-4 covers plugging and inching duty, where the contactor sees higher electrical wear. The IP20 finger-safe enclosure (VDE 0106) suits panel-mount installations where the contactor is behind a cabinet door.

Mechanical and environmental tolerance

Rated for shock and vibration per IEC 60068-2-27 and IEC 60068-2-6: the contactor holds closed through 10 Gn on Y and Z axes, 6 Gn on X axis (11 ms half-sine). Vibration resistance is 4 Gn closed, 2 Gn open across 5–300 Hz. Storage temperature spans -50 to 80 °C; operating ambient is -25 to 50 °C. The protective treatment conforms to IEC 60068 and DIN 50016 for damp heat and corrosive atmospheres.

Depth 57 mm, width 90 mm, height 58 mm. The 1 NC auxiliary is wired into the reversing interlock logic.

Frequently asked questions

What replaces LC2K0601K72?

No official successor order code is provided in the lifecycle record. For a drop-in replacement, an RFQ is needed to cross-reference the ratings (3P, AC-3 6 A at ≤440 V, 100 V AC coil, 1 NC) against current TeSys K or TeSys Deca series contactors.

What compliance documentation is available for this part?

The part carries flame retardance V1 per UL 94, conforms to NF F 16-101/102 for rail fire/smoke requirements, and protective treatment per IEC 60068 and DIN 50016. RoHS, REACH, and UL declarations are provided at time of order.

What is the depth of LC2K0601K72?

57 mm.

What series does LC2K0601K72 belong to?

TeSys K.