Rated for AC-3 and AC-4 utilization categories, it switches motor loads up to 6 A at 440 V AC — the AC-3 rating governs the motor starting current, while AC-4 covers plugging or inching duty where the contactor makes and breaks stalled-rotor current. The 256 V AC coil is the control voltage you need to supply; the contactor pulls in cleanly on that nominal and drops out reliably below the release threshold. Built into the TeSys K family, this reversing contactor is sized for control panels where direction reversal of a small motor (conveyor, fan, actuator) is required. The IP20 finger-safe enclosure meets VDE 0106, so it's suitable for enclosed panel environments where accidental contact with live parts must be prevented.

TeSys K LC2K0601W7 reversing contactor, 3P, 6 A AC-3, 256 V
Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 6 A, 1 NC, 256 V AC coil, preassembled with reversing power busbar.
Specifications
| Parameter | Value |
|---|---|
| Product / component type | Reversing contactor |
| Series / range | TeSys |
| Application | Motor control |
| Parameter | Value |
|---|---|
| Rated operational voltage (Ue) | Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit |
| Utilisation category | AC-3 AC-4 |
| Parameter | Value |
|---|---|
| Pole configuration | 3P |
| Parameter | Value |
|---|---|
| IP degree of protection | IP20 conforming to VDE 0106 |
| Operating altitude | 2000 m without derating |
| Mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Protective treatment / pollution degree | TC conforming to IEC 60068 TC conforming to DIN 50016 |
| Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Parameter | Value |
|---|---|
| Width | 90 mm |
| Height | 58 mm |
| Depth | 57 mm |
Product details
Frequently asked questions
What is the closest alternative to the LC2K0601W7 in the TeSys K family?
Within the TeSys K family, the closest peer would be a reversing contactor with the same pole configuration and coil voltage but a different auxiliary contact arrangement. The LC2K0601W7 carries 1 NC auxiliary; if you need 1 NO instead, the sibling with that contact configuration is the direct swap. Both share the same footprint, busbar, and AC-3 rating.
What is the depth of the LC2K0601W7?
The depth is 57 mm, with a width of 90 mm and height of 58 mm.
What compliance documentation is available for the LC2K0601W7?
The part carries flame retardance V1 per UL 94, plus compliance with NF F 16-101 and NF F 16-102 for railway fire-smoke. It is IP20 per VDE 0106. For RoHS, REACH, and full UL/IEC certification, the manufacturer's declaration pack is available through the standard documentation portal.