Skip to main content
Schneider Electric LC2K06103K7 — Contactors

Schneider TeSys K LC2K06103K7 reversing contactor, 3P, AC-3

MPNLC2K06103K7
Active

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 6 A, 1 NO, 100 V AC coil, IP20 finger-safe.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC2K06103K7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K06103K7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4
LC2K06103K7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K06103K7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K06103K7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The coil is 100 V AC, and the auxiliary contact block includes 1 NO.

The 6 A AC-3 rating at <=440 V is the headline motor-switching current — it tells you this contactor can start and stop a 3-phase induction motor drawing up to 6 A under full-load running conditions. For a 400 V supply, that corresponds roughly to a 3 kW motor (4 HP). The AC-4 rating covers the more severe duty of reversing or jogging while the motor is already under load, so if your application cycles direction frequently (conveyor reversals, crane travel), the contactor is rated for that stress. The IP20 finger-safe enclosure (per VDE 0106) means it is safe for panel mounting without additional shrouding — the terminals are protected against accidental contact by a standard test finger.

Frequently asked questions

What is the closest alternative to LC2K06103K7 in the TeSys K family?

Within the same TeSys K reversing contactor range, the closest sibling would be a variant with a different coil voltage (e.g., 24 V AC or 230 V AC) or a different auxiliary contact configuration. The mechanical footprint and AC-3 rating are identical across the family; the coil voltage is the deciding factor for fit.

What is the depth of LC2K06103K7?

The depth is 57 mm.

What compliance documentation is available for LC2K06103K7?

The contactor carries V1 flame-retardance per UL 94, meets NF F 16-101 and NF F 16-102 for railway fire safety, and has IP20 finger-safe protection per VDE 0106. The manufacturer typically provides a RoHS and REACH declaration on request.

MPN
LC2K06103K7