LC2K09004L7 — Identification
ParameterValue
Product / component typeChangeover contactor
Series / rangeTeSys
ApplicationResistive load
LC2K09004L7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC2K09004L7 — Contacts & Poles
ParameterValue
Pole configuration4P
LC2K09004L7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K09004L7 — Approvals
ParameterValue
StandardsNF C 63-110 IEC 60947 BS 5424 VDE 0660
LC2K09004L7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

It is designed for controlling the direction of single-phase or three-phase motors up to the rated breaking capacity, typically in conveyor, pump, or fan reversing applications where a single contactor package simplifies panel wiring. The control circuit operates on 200-208 V AC at 50/60 Hz, with a pickup range of 0.85 to 1.1 Uc and a dropout range of 0.2 to 0.75 Uc. Coil inrush is 30 VA at 20 °C, and heat dissipation is 1.3 W. The mechanical interlock prevents both contactors from closing simultaneously, which is essential for reversing duty.

Screw clamp terminals accept one or two conductors: solid 1.5-4 mm², flexible without ferrule 0.75-4 mm², or flexible with ferrule 0.34-2.5 mm². Tightening torque is 1.3 Nm using a No 2 Philips or 6 mm flat screwdriver. The preassembled reversing busbar saves panel space and reduces wiring errors compared to building the reversing circuit from two separate contactors and an interlock module. The part is protected against thermal shock and humidity per IEC 60068 and DIN 50016 (TC treatment).

Frequently asked questions

What is the control voltage for this contactor?

The control circuit voltage is 200-208 V AC at 50/60 Hz. The operating range is 0.85 to 1.1 Uc for pickup, and dropout occurs between 0.2 and 0.75 Uc.

What standards does the LC2K09004L7 comply with?

It complies with IEC 60947, NF C 63-110, BS 5424, VDE 0660, UL 508, and CSA C22.2 No 14. It also meets NF F 16-101/102 for railway fire behavior and UL 94 V1 flame retardance.

What is the difference between this and a standard LC1K contactor?

The LC2K09004L7 is a changeover (reversing) contactor — two contactors mechanically interlocked and pre-wired with a reversing busbar in one package. A standard LC1K is a single contactor. For reversing a motor, the LC2K saves panel space and eliminates the risk of wiring the interlock incorrectly.

MPN
LC2K09004L7