Skip to main content
Schneider Electric LC2K09103L7 — Contactors

Schneider Electric LC2K09103L7 TeSys K Reversing Contactor,

MPNLC2K09103L7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 9 A, 1 NO, 200...208 VAC coil, IP20, depth 57 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K09103L7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC2K09103L7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-1 AC-3 AC-4
LC2K09103L7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K09103L7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K09103L7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

It carries an AC-3 rating of 9 A at up to 440 V, meaning it can switch a 3-phase induction motor load up to that current under full-load starts. The coil is wound for 200-208 VAC 50/60 Hz, so it drops into control panels where a 208 V control transformer is standard.

At 57 mm deep, 90 mm wide, and 58 mm tall, this reversing contactor is sized for DIN-rail or panel-mount enclosures where space is tight. The IP20 finger-safe terminals (per VDE 0106) mean it belongs inside a locked cabinet — not in a washdown zone.

Frequently asked questions

What is the closest alternative to the LC2K09103L7?

No official successor is listed in the lifecycle record. A direct pin-compatible replacement from the TeSys K family is not confirmed by the manufacturer. For a BOM line, the best path is to source the exact obsolete code through surplus stock or evaluate a current TeSys K reversing contactor with the same coil voltage and AC-3 rating — but that requires checking the physical footprint and terminal layout against the existing panel.

What are the key ratings for the LC2K09103L7?

It is a 3-pole reversing contactor rated AC-3 at 9 A up to 440 V, with a 200-208 VAC coil. The utilisation categories cover AC-1, AC-3, and AC-4, so it handles resistive loads, motor starts, and plugging/inching duty. Dimensions are 57 mm deep, 90 mm wide, 58 mm tall.

What compliance documentation does this part carry?

The contactor meets UL 94 V1 flame retardance, NF F 16-101 and NF F 16-102 for rail fire safety, and IEC 60068 / DIN 50016 for protective treatment. IP20 per VDE 0106. Shock and vibration tested to IEC 60068-2-27 and IEC 60068-2-6.

MPN
LC2K09103L7