Skip to main content
Schneider Electric LC2K09105D7 — Contactors

Schneider TeSys K LC2K09105D7 Reversing Contactor, 3P, 9A AC

MPNLC2K09105D7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤ 440 V 9 A, 1 NO, 42 V AC coil, preassembled with reversing power busbar.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K09105D7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LC2K09105D7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-1 AC-3
LC2K09105D7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K09105D7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K09105D7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider TeSys K LC2K09105D7 is a 3-pole reversing contactor rated for motor control and resistive loads. Rated AC-3 at 9 A up to 440 V, it handles reversing duty on motors. The AC-1 rating covers resistive loads at the same current level.

Frequently asked questions

What replaces the LC2K09105D7?

There is no direct pin-compatible successor from Schneider. A current-production reversing contactor from the TeSys Deca or TeSys F range would be the functional replacement, but you must verify the mounting footprint, busbar arrangement, and coil voltage compatibility before substituting.

What are the key ratings of the LC2K09105D7?

It is a 3-pole reversing contactor rated AC-3 at 9 A up to 440 V, with a 42 V AC coil. The power circuit is rated 690 V AC. It is preassembled with a reversing power busbar.

What compliance documentation does Schneider provide for this part?

The contactor carries a V1 flame retardance rating per UL 94, and meets NF F 16-101 and NF F 16-102 requirements for railway fire-smoke-toxicity. It is IP20 rated per VDE 0106. Protective treatment conforms to IEC 60068 and DIN 50016 for environmental resistance.

MPN
LC2K09105D7