LC2K1201C7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC2K1201C7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-1 AC-3 AC-4
LC2K1201C7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1201C7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1201C7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LC2K1201C7 is a TeSys K reversing contactor from Schneider Electric, a 3-pole device rated for AC-3 duty at 12 A up to 440 V, with a 36 V AC coil and one NC auxiliary contact. The AC-3 rating of 12 A at 440 V means it handles motor switching within that current envelope — typical for small conveyors, pumps, or fan starters.

The 36 V AC coil is a specific control voltage — not the common 24 V DC or 110/230 V AC found in most panels. If your control circuit runs 36 V AC, this fits; otherwise you'd need a coil-voltage variant or an interposing relay. The 1 NC auxiliary is built in, so no separate aux block is required for a basic safety or status feedback loop. IP20 protection (VDE 0106) means it's finger-safe but not sealed — mount inside an enclosure, not in washdown or outdoor locations. Mechanical robustness specs show it withstands 10–15 G shocks in closed position and 4 G vibration up to 300 Hz — adequate for typical machine-mounted panels but not extreme off-road or high-vibration applications.

Frequently asked questions

What are the key ratings for this contactor?

It is a 3-pole reversing contactor rated 12 A in AC-3 duty at ≤440 V, with a 36 V AC coil and one NC auxiliary contact. It also covers AC-1 and AC-4 utilisation categories.

What is the depth of the LC2K1201C7?

The depth is 57 mm, with a width of 90 mm and height of 58 mm.

Which product family does this belong to?

It is part of the TeSys K range from Schneider Electric.