Skip to main content
Schneider Electric LC2K1201K7 — Contactors

Schneider TeSys K LC2K1201K7 Reversing Contactor, 3P, 12A AC

MPNLC2K1201K7
Obsolete

Schneider Electric TeSys K reversing contactor, LC2K1201K7, 3P, AC-3 12A at ≤440V, 100V AC coil, IP20, depth 57 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K1201K7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LC2K1201K7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-1 AC-4 AC-3
LC2K1201K7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1201K7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1201K7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The unit is rated for utilization categories AC-1, AC-3, and AC-4, with a specific AC-3 rating of 12 A at ≤440 V.

The AC-4 rating covers plugging and inching duty, so the contactor is rated for the higher switching frequency and electrical wear those operations demand. The 100 V AC coil means the control circuit must supply 100 V AC nominal; verify your control transformer or PLC output matches this voltage, as a mismatch will prevent pickup or cause coil burnout.

Physical Integration and Compliance

The contactor measures 90 mm wide by 58 mm high by 57 mm deep. These dimensions fit a standard DIN-rail footprint for the TeSys K form factor; plan for the depth when routing wiring behind the panel. The flame retardance rating is V1 per UL 94, and it also meets NF F 16-101 and NF F 16-102 requirements—relevant for rail or transit applications where fire-smoke-toxicity standards apply. Operating altitude is 2000 m without derating; above that, the dielectric withstand and thermal dissipation will need recalculation. The protective treatment conforms to IEC 60068 and DIN 50016 for resistance to corrosive atmospheres.

Frequently asked questions

What are the key ratings for this contactor?

The LC2K1201K7 is a 3-pole reversing contactor rated 12 A in AC-3 duty at ≤440 V, with a 100 V AC coil. It covers utilization categories AC-1, AC-3, and AC-4. Dimensions are 90 x 58 x 57 mm (WxHxD).

What compliance documentation is available for this part?

The contactor carries a V1 flame retardance rating per UL 94, and also conforms to NF F 16-101 and NF F 16-102 for rail applications. The protective treatment follows IEC 60068 and DIN 50016. The IP20 degree of protection is per VDE 0106. Standard Schneider documentation for the TeSys K range applies.

What is the depth of the LC2K1201K7?

The depth is 57 mm. This is the dimension behind the panel face, critical for enclosure depth clearance and wiring bend radius.

MPN
LC2K1201K7