Skip to main content
Schneider Electric LC2K1210C7 — Contactors

Schneider TeSys K LC2K1210C7 Reversing Contactor, 12 A AC-3,

MPNLC2K1210C7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 12 A at 440 V, 36 VAC coil, preassembled with reversing power busbar.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K1210C7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC2K1210C7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-1 AC-3
LC2K1210C7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1210C7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1210C7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric TeSys K LC2K1210C7 is a reversing contactor, 3-pole, rated for AC-3 duty at 12 A up to 440 V with a 36 V AC coil. It comes preassembled with the reversing power busbar, saving panel wiring time on motor-reversing circuits for conveyors, hoists, or pump direction control.

The AC-3 rating of 12 A at 440 V governs motor switching — that's the current the contactor can make and break across a standard squirrel-cage induction motor. The 36 V AC coil means it pulls in reliably on a control transformer at that voltage; verify your control circuit supply matches before wiring. The IP20 finger-safe terminals (VDE 0106) suit enclosed panel mounting, not open washdown areas.

The contactor handles 10 Gn shock on X axis when closed, 15 Gn on Y and Z — robust for industrial machinery with vibration. Flame retardance meets UL 94 V1 and NF F 16-101/102, relevant for rail and transport applications.

Frequently asked questions

What is the closest alternative to LC2K1210C7 in the TeSys family?

Within the TeSys K range, the closest functional equivalent would be a current-production reversing contactor with matching pole count, AC-3 current rating, and coil voltage. The exact replacement depends on your mounting and busbar arrangement — the preassembled reversing busbar on this unit means a drop-in substitute may require a different mechanical kit.

What is the depth of LC2K1210C7?

The depth is 57 mm. Combined with 90 mm width and 58 mm height, it fits a standard DIN-rail footprint for a reversing contactor assembly.

What compliance documentation is available for LC2K1210C7?

The contactor carries VDE 0106 IP20 protection, UL 94 V1 flame retardance, and NF F 16-101/102 compliance for rail. It is part of the Schneider TeSys range, so standard RoHS and REACH declarations are available from the manufacturer's documentation portal.

MPN
LC2K1210C7