Skip to main content
Schneider Electric LC2K16015F72 — Contactors

TeSys K LC2K16015F72 Reversing Contactor, 3P, 16A AC-3, 110V

MPNLC2K16015F72
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NC, 110 V AC coil, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K16015F72 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K16015F72 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4
LC2K16015F72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K16015F72 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K16015F72 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric TeSys K LC2K16015F72 is a reversing contactor — a preassembled unit with the reversing power busbar already fitted. It is a 3-pole device rated for AC-3 and AC-4 duty. The rating is 16 A at ≤440 V in AC-3. The coil is 110 V AC.

The AC-4 rating covers reversing and plugging duty, where the contactor breaks at full load current, so that rating is typically lower; the evidence does not give a separate AC-4 current figure, but the dual utilization category confirms the contactor is built for the mechanical stress of frequent reversals. The 690 V AC rated operational voltage on the power circuit means it can also switch on a 690 V line if derated — but the 16 A AC-3 rating is only valid up to 440 V. Above that, the current must be reduced per the manufacturer's derating curve. The IP20 finger-safe terminals are standard for enclosed panel mounting; no washdown protection here.

The shock and vibration ratings are solid for a reversing contactor that sees frequent mechanical cycling: it holds closed through 10 Gn on Y and Z axes, and 15 Gn on X. The V1 flame retardance rating per UL 94 means the housing material self-extinguishes — relevant for panel certification.

The IP20 terminals accept standard ring or fork crimp lugs. The 1 NC auxiliary contact is built in — useful for a feedback signal to the PLC or to interlock the forward and reverse coils in the safety circuit. The coil is 110 V AC, so verify your control transformer voltage matches before wiring.

Frequently asked questions

What are the key ratings of the LC2K16015F72?

It is a 3-pole reversing contactor rated 16 A in AC-3 at ≤440 V, with a 110 V AC coil. The power circuit is rated for 690 V AC. It has IP20 finger-safe protection.

How do I source this obsolete part?

Through the surplus and broker channel. We can quote it to order against an RFQ — there is no factory stock or lead time.

MPN
LC2K16015F72