Specifications

LC2K16017E7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K16017E7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3
LC2K16017E7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K16017E7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K16017E7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The 48 V AC coil and 16 A rating at ≤440 V AC-3 make it a fit for small reversing drives — conveyors, hoists, or pump pairs where direction change is part of the cycle. Rated operational voltage goes up to 690 V AC 50/60 Hz on the power circuit, and the contactor carries IP20 finger-safe protection per VDE 0106, so it's suited for enclosed panel mounting where accidental contact is a concern. Altitude capability to 2000 m without derating covers most standard installations.

Frequently asked questions

What is the closest alternative to the LC2K16017E7?

No official successor order code is listed. A parametric replacement from the current TeSys range would need to match the 3-pole reversing configuration, 48 V AC coil, and 16 A AC-3 rating — but that requires cross-referencing against active catalog numbers, which is not documented in the lifecycle record for this exact variant.

What are the key ratings for this contactor?

AC-3 rated 16 A at ≤440 V, 48 V AC coil, 3 NO power poles, 1 NC auxiliary contact, IP20 finger-safe protection, and operational voltage up to 690 V AC 50/60 Hz.

What compliance documentation is available?

Flame retardance is V1 per UL 94 and also meets NF F 16-101 and NF F 16-102. Protective treatment conforms to IEC 60068 and DIN 50016. The part carries IP20 per VDE 0106.

MPN
LC2K16017E7