Schneider Electric LC2K1601C7

TeSys K LC2K1601C7 reversing contactor, 3P, 16 A AC-3, 36 VA

MPNLC2K1601C7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 16 A, 1 NC, 36 V AC coil, IP20, 57 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K1601C7 key specifications
ParameterValue
Product or component typeReversing contactor
[Ue] rated operational voltagePower circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Power pole contact composition3 NO
Poles description3P
Utilisation categoryAC-4 AC-3
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Depth57 mm
Width90 mm
Height58 mm
RangeTeSys
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102

All specifications

LC2K1601C7 additional specifications
ParameterValue
Device short nameLC2K
Device applicationControl
Device presentationPreassembled with reversing power busbar
Protective treatmentTC conforming to IEC 60068 TC conforming to DIN 50016
Contactor applicationMotor control
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Ambient air temperature for storage-50...80 °C
Ambient air temperature for operation-25...50 °C

Product details

The LC2K1601C7 is a TeSys K reversing contactor from Schneider Electric — a 3-pole unit preassembled with a reversing power busbar, rated for AC-3 duty up to 440 V at 16 A, with a 36 V AC coil and one NC auxiliary contact. The AC-3 rating (16 A at ≤440 V) means it handles starting and stopping of squirrel-cage motors under load — the typical duty for a reversing contactor in a motor-reversing or star-delta circuit. The AC-4 utilisation category also covers plugging and inching, so it's rated for the higher electrical stress of reversing under full load. The 36 V AC coil is a control-voltage common in older European panel designs; verify your control transformer taps before wiring.

At 57 mm deep, 90 mm wide, and 58 mm high, the LC2K1601C7 fits a standard DIN-rail footprint — common in control panels where space is tight. Operating temperature range is -25 to 50 °C, with storage from -50 to 80 °C, and it operates without derating up to 2000 m altitude — fine for most industrial sites but check if your installation is above that threshold.

The contactor carries a V1 flame-retardance rating per UL 94 and meets NF F 16-101/102 for railway fire behaviour. It is also protected against corrosive atmospheres per IEC 60068 and DIN 50016 (TC treatment). Shock and vibration ratings per IEC 60068-2-27 and IEC 60068-2-6 are specified for both closed and open contactor states — useful for applications on mobile equipment or near heavy machinery.

Frequently asked questions

What is the closest pin-compatible alternative to the LC2K1601C7?

No official direct replacement is listed in the lifecycle record. A parametric cross-reference to a current TeSys K or TeSys Deca reversing contactor with the same coil voltage and pole count would need to be validated by the integrator — pinout and mounting may differ.

What is the LC2K1601C7's depth?

The listed depth is 57 mm.

What range does the LC2K1601C7 belong to?

It is part of the Schneider Electric TeSys range, specifically the TeSys K series.

What compliance documentation does Schneider provide for the LC2K1601C7?

The contactor carries a V1 flame-retardance rating per UL 94 and meets NF F 16-101/102 for railway fire behaviour. It is also protected against corrosive atmospheres per IEC 60068 and DIN 50016 (TC treatment). Shock and vibration ratings per IEC 60068-2-27 and IEC 60068-2-6 are specified.

MPN