The LC2K1601J7 is a TeSys K reversing contactor from Schneider Electric — a 3-pole unit rated for AC-3 duty at 16 A up to 440 V, with a 12 V AC coil and one NC auxiliary contact. It ships preassembled with the reversing power busbar, so you don't need to source and fit the mechanical interlock and busbar separately. That saves panel-build time when wiring a reversing starter for a motor that runs forward and reverse.
TeSys K LC2K1601J7 reversing contactor, 3P, 16 A AC-3, 12 VA
Schneider Electric TeSys K reversing contactor, 3-pole, AC-3 <=440 V 16 A, 1 NC auxiliary, 12 V AC coil, preassembled with reversing power busbar.
Specifications
Identification
| Parameter | Value |
|---|---|
| Product / component type | Reversing contactor |
| Series / range | TeSys |
| Application | Motor control |
Ratings & Performance
| Parameter | Value |
|---|---|
| Rated operational voltage (Ue) | Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit |
| Utilisation category | AC-3 AC-4 |
Contacts & Poles
| Parameter | Value |
|---|---|
| Pole configuration | 3P |
Environmental
| Parameter | Value |
|---|---|
| IP degree of protection | IP20 conforming to VDE 0106 |
| Operating altitude | 2000 m without derating |
| Mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Protective treatment / pollution degree | TC conforming to IEC 60068 TC conforming to DIN 50016 |
| Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
Mechanical
| Parameter | Value |
|---|---|
| Width | 90 mm |
| Height | 58 mm |
| Depth | 57 mm |
Product details
Frequently asked questions
What are the key ratings I need to check for fit?
The headline rating is AC-3 <=440 V at 16 A, which determines motor-switching capacity. The coil is 12 V AC. The contactor is 3-pole with one NC auxiliary. IP20 rated for panel use. Dimensions: 90 mm wide, 58 mm high, 57 mm deep.
What compliance documentation does this brand provide for LC2K1601J7?
The contactor carries V1 flame retardance per UL 94, and also meets NF F 16-101 and NF F 16-102 for rail fire safety. IP20 per VDE 0106. Shock and vibration ratings are per IEC 60068-2-27 and IEC 60068-2-6. Protective treatment conforms to IEC 60068 and DIN 50016.