Skip to main content
Schneider Electric LC2K1601Y7 — Contactors

Schneider Electric TeSys K LC2K1601Y7 Reversing Contactor, 3

MPNLC2K1601Y7
Active

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 16 A, 1 NC, 660...690 V AC, preassembled with reversing power busbar.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC2K1601Y7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control

Ratings & Performance

LC2K1601Y7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3

Contacts & Poles

LC2K1601Y7 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC2K1601Y7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102

Mechanical

LC2K1601Y7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric TeSys K LC2K1601Y7 is a 3-pole reversing contactor rated for motor control in AC-3 and AC-4 utilisation categories. Its headline rating is 16 A at 440 V AC in AC-3 duty, which means it switches three-phase induction motors up to that current during starting and running — the AC-3 rating is the one that governs real motor load fit, not the higher resistive (AC-1) figure. Rated operational voltage on the power circuit is 690 V AC 50/60 Hz, so it handles standard 400/480 V line supplies with margin. The 1 NC auxiliary contact is built in, covering interlocking or status feedback without an add-on block.

IP20 finger-safe protection (per VDE 0106) means it can sit in a panel with other live parts without additional shrouding, though the panel door or cover remains the primary safeguard.

Mechanical robustness for vibrating environments

Rated for shocks up to 15 Gn on Y and Z axes (contactor closed) and 10 Gn on X axis, per IEC 60068-2-27. Vibration resistance is 4 Gn closed, 2 Gn open across 5–300 Hz. That puts it in the range for conveyor drives, pump skids, and compressor panels where mechanical shock is a concern.

Frequently asked questions

What are the key ratings for this reversing contactor?

AC-3 motor rating is 16 A at 440 V AC; rated operational voltage of the power circuit is 690 V AC 50/60 Hz. It has 3 NO power poles and 1 NC auxiliary contact. Coil voltage is 660...690 V AC.

What is the depth of the LC2K1601Y7?

Depth is 57 mm, width 90 mm, height 58 mm — a compact DIN-rail footprint.

What compliance documentation is available for this part?

Flame retardance meets UL 94 V1 and NF F 16-101/102. Protective treatment complies with IEC 60068 and DIN 50016. IP20 per VDE 0106. The manufacturer typically provides RoHS and REACH declarations on request.

MPN