The Schneider LC2K16105V7 is a TeSys K reversing contactor — a 3-pole, 3 NO main contact device rated for motor control in AC-3 and AC-4 duty. It's preassembled with a reversing power busbar, saving panel space and wiring time on a reversing starter build. Rated operational voltage on the power circuit is 690 V AC at 50/60 Hz, with the AC-3 switching current specified at 16 A up to 440 V. The coil is 400 V AC, so it pulls in directly from a 400 V line or control transformer without an intermediate relay.

Schneider TeSys K LC2K16105V7 Reversing Contactor, 16 A, 400
Schneider TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO, 400 V AC coil, preassembled with reversing power busbar, IP20.
Specifications
| Parameter | Value |
|---|---|
| Product / component type | Reversing contactor |
| Series / range | TeSys |
| Application | Motor control |
| Parameter | Value |
|---|---|
| Rated operational voltage (Ue) | Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit |
| Utilisation category | AC-4 AC-3 |
| Parameter | Value |
|---|---|
| Pole configuration | 3P |
| Parameter | Value |
|---|---|
| IP degree of protection | IP20 conforming to VDE 0106 |
| Operating altitude | 2000 m without derating |
| Mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Protective treatment / pollution degree | TC conforming to IEC 60068 TC conforming to DIN 50016 |
| Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Parameter | Value |
|---|---|
| Width | 90 mm |
| Height | 58 mm |
| Depth | 57 mm |
Product details
Frequently asked questions
What is the closest alternative to LC2K16105V7?
No official successor is listed. A parametric match from the current TeSys K or TeSys Deca range with the same coil voltage (400 V AC) and AC-3 rating (16 A at 440 V) would be the closest functional replacement, but pinout and busbar arrangement should be verified against the existing panel layout.
What are the key ratings of LC2K16105V7?
It's a 3-pole reversing contactor rated AC-3 16 A at 440 V, with a 400 V AC coil. Power circuit rated 690 V AC 50/60 Hz. IP20 protection. Dimensions: 90 x 58 x 57 mm (W x H x D).
What compliance documentation does Schneider provide for LC2K16105V7?
The part carries flame retardance V1 per UL 94 and conforms to NF F 16-101 and NF F 16-102 (railway fire standards). Protective treatment conforms to IEC 60068 and DIN 50016. IP20 per VDE 0106. Shock and vibration ratings per IEC 60068-2-27 and IEC 60068-2-6 are listed.