Skip to main content
Schneider Electric LC2K16107J72 — Contactors

TeSys K LC2K16107J72 reversing contactor, 3P, 16 A, 12 V AC

MPNLC2K16107J72
Active

Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO, 12 V AC coil, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K16107J72 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K16107J72 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4
LC2K16107J72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K16107J72 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K16107J72 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

Rated for AC-3 and AC-4 duty, it switches motor loads up to 16 A at ≤440 V AC, with a maximum operational voltage of 690 V AC 50/60 Hz on the power circuit. The 12 V AC coil pulls in to reverse the motor; the signalling circuit is isolated at 10 MOhm.

This part is marked obsolete by the manufacturer. The IP20 finger-safe enclosure (VDE 0106) and V-0 flame retardance (UL 94) mean it can still be swapped into an existing panel without re-certifying the assembly, but plan for a last-time buy if you need spares.

The reversing busbar is preassembled, so installation is a single-unit swap — no loose wiring between two contactors.

Frequently asked questions

What is the closest alternative to LC2K16107J72 in the TeSys family?

No official successor order code is provided in the lifecycle record. A direct replacement would need to match the 3-pole reversing contactor form factor, 16 A AC-3 rating, and 12 V AC coil voltage — but without a published cross-reference, verify fit by comparing the mounting footprint and coil characteristics against a current TeSys K or TeSys Deca reversing contactor.

MPN