Skip to main content
Schneider Electric LC2K16107M7 — Contactors

Schneider TeSys K LC2K16107M7 Reversing Contactor, 3P, AC-3

MPNLC2K16107M7
Active

Schneider Electric TeSys K series, reversing contactor, 3P, AC-3 <= 440 V 16 A, 1 NO, 220...230 V AC coil, IP20.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC2K16107M7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control

Ratings & Performance

LC2K16107M7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4

Contacts & Poles

LC2K16107M7 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC2K16107M7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102

Mechanical

LC2K16107M7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

It's a 3-pole (3P) device rated for AC-3 and AC-4 utilisation categories, meaning it's built for switching squirrel-cage motors under full load and for plugging or inching duty. The headline rating: AC-3 at ≤440 V, 16 A, which covers motor control up to roughly 7.5 kW at 400 V three-phase.

That 57 mm depth is the key clearance number for shallow enclosures — it fits standard 200 mm deep cabinets with room for wiring ducts. The preassembled reversing busbar eliminates the need for external cross-wiring between two contactors, which also reduces the chance of a phase-reversal wiring error during commissioning.

Frequently asked questions

What is the closest alternative in the TeSys family?

Within the TeSys K range, the LC2K09007M7 is a smaller frame (9 A AC-3) with the same coil voltage and reversing busbar preassembled. If you need higher current, the LC2K25007M7 (25 A AC-3) is the next step up. All share the same 220...230 V AC coil and 3-pole reversing format, so panel layout and wiring stay consistent — only the power rating changes.

MPN
LC2K16107M7