Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO auxiliary, 120 V AC coil, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC2K1610G7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K1610G7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4
LC2K1610G7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1610G7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1610G7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LC2K1610G7 is a Schneider Electric TeSys K reversing contactor — three-pole, rated 16 A in AC-3 duty at up to 440 V, with a 120 V AC coil and one normally-open auxiliary contact. It ships preassembled with the reversing power busbar.

The LC2K1610G7 is marked obsolete. We source these to order against an RFQ.

The 16 A AC-3 rating is the load-switching limit — it is not a continuous thermal current (Ith). The 120 V AC coil pulls in at 120 V nominal.

Frequently asked questions

What are the key ratings for this contactor?

Three-pole reversing contactor, AC-3 rated 16 A at ≤440 V, 120 V AC coil, one NO auxiliary contact. IP20 finger-safe, operates at -25 to 50 °C ambient, altitude 2000 m without derating.

What compliance documentation does Schneider provide for this part?

The contactor carries UL 94 V1 flame retardance and NF F 16-101/102 compliance. No RoHS/REACH declaration is listed in the available specs, but Schneider typically includes those in the product certificate — request it with the RFQ.