Skip to main content
Schneider Electric LC2K1610P7 — Contactors

TeSys K LC2K1610P7 reversing contactor, 3P, 16A AC-3, 230V A

MPNLC2K1610P7
Active

Schneider Electric TeSys K reversing contactor, LC2K1610P7, 3P, AC-3/AC-3e 16 A at ≤440 V, 1 NO auxiliary contact, 230 V AC coil, IP20, preassembled reversing busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC2K1610P7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K1610P7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-3e AC-4
LC2K1610P7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1610P7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1610P7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

It switches three-phase induction motors up to 16 A in AC-3 duty (≤440 V), which covers most small conveyors, pumps, and fan drives that need forward/reverse control. The 230 V AC coil is standard for European panel voltages; the single NO auxiliary contact gives you one feedback or interlock signal without adding a separate block.

AC-3e extends that to energy-efficient motors with slightly different switching characteristics; The 3 NO power poles handle all three phases; the reversing busbar is already in place, so you only need to connect the coil and motor leads. At 57 mm deep, 90 mm wide, and 58 mm tall, this fits standard 35 mm DIN-rail enclosures with room for adjacent motor starters.

Vibration resistance to 4 Gn closed and 2 Gn open (5–300 Hz) keeps the contacts from chattering on a running conveyor line. Shock ratings of 10–15 Gn closed on Y and Z axes suit it for machine-tool cabinets near presses or punch stations.

Frequently asked questions

What are the key ratings for this reversing contactor?

Three-pole, AC-3/AC-3e rated 16 A at ≤440 V, AC-4 rated for plugging duty, 230 V AC coil, one NO auxiliary contact, IP20 finger-safe protection, and it ships preassembled with a reversing power busbar.

What is the physical size of the LC2K1610P7?

57 mm deep, 90 mm wide, and 58 mm tall — fits standard 35 mm DIN-rail enclosures.

What compliance documentation is available for this part?

The contactor carries V1 flame retardance per UL 94, meets NF F 16-101/102 for railway fire behaviour, and is IP20 rated per VDE 0106. Protective treatment conforms to IEC 60068 and DIN 50016 for corrosion resistance.

MPN
LC2K1610P7