Skip to main content
Schneider Electric LC2K1610N7 — Contactors

Schneider Electric LC2K1610N7 TeSys K Reversing Contactor, 1

MPNLC2K1610N7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO, 400…415 V AC coil, preassembled with reversing power busbar, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC2K1610N7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control
LC2K1610N7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-3
LC2K1610N7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K1610N7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K1610N7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC2K1610N7 is a TeSys K reversing contactor — a 3-pole unit rated for AC-3 duty at 16 A up to 440 V, with a 400…415 V AC coil and one normally open auxiliary contact.

The AC-3 rating at 16 A means it directly switches a three-phase induction motor up to roughly 7.5 kW at 400 V — the category covers starting and running of squirrel-cage motors, which is the dominant load for a reversing contactor in conveyor, hoist, or pump applications. The 690 V AC rated operational voltage on the power circuit gives headroom for 480 V or 575 V systems, but the AC-3 current must be derated above 440 V per the thermal curve.

Frequently asked questions

What replaces the LC2K1610N7?

There is no official pin-compatible replacement in the TeSys K series. A redesign to a current TeSys D reversing contactor (e.g., LC2D series) is the typical path, but the footprint, coil voltage, and auxiliary contact arrangement must be verified against the existing panel layout.

What are the key ratings of the LC2K1610N7?

It is a 3-pole reversing contactor rated AC-3 at 16 A up to 440 V, with a 400…415 V AC coil and one NO auxiliary contact. The power circuit is rated for 690 V AC, and the unit is IP20 with an operating temperature range of -25…50 °C.

MPN